Impedance Selection

Use the switch located under the microphone base, near the cable entry, to select high (

HI

) or low (

LO

) impedance.

Use the low-impedance position for long cable lengths under conditions of severe hum disturbance. Use Shure Model A95 

Series Line Matching Transformers when using a low-impedance microphone line with a high-impedance amplifier input.

Logic Connections

The RED and BLACK leads may be used to control an external relay or switching circuit.

Audio Connections

Unbalanced high-impedance operation:

Set the impedance switch to the 

HI

 position (as shipped). Connect the GREEN cable lead and the shield to the amplifier chas­

sis ground. The WHITE cable lead is the "hot" conductor.

Balanced-line low-impedance operation:

Set the impedance switch to the 

LO

 position. Connect the shield to the amplifier chassis ground. The WHITE and GREEN ca­

ble leads are the "hot" conductors.

Cable-to-Connector Wiring

Input Type

Wire Color

Function

XLR Connector

1/4 in. Phone Plug

Unbalanced

White

Audio

Pin 2

Tip

Green

Audio Ground

Pin 3

Sleeve

Shield

Chassis Ground

Pin 1

Sleeve

Balanced

White

Audio +

Pin 2

Tip

Green

Audio -

Pin 3

Ring

Shield

Chassis Ground

Pin 1

Sleeve

Summary of Contents for 522

Page 1: ...522 Voice Communication Microphone Online user guide for Shure Version 4 2019 I ...

Page 2: ... 3 General Description 3 Features 3 Press To Talk Switch Operation 3 Impedance Selection 4 Logic Connections 4 Audio Connections 4 Unbalanced high impedance operation 4 Balanced line low impedance operation 4 Specifications 5 Accessories 7 Replacement Parts 7 Certifications 7 ...

Page 3: ...Features Dual impedance 19 to 300 ohms or High Impedance change switch for convenient change over Finger tip control bar locking or non locking action to actuate microphone circuit and an external relay or control circuit Long life swtich to satisfy rigorous requirements of communications and paging systems Sturdy high impact ARMO DUR base and microphone case Adjustable microphone height Dependabl...

Page 4: ...io Connections Unbalanced high impedance operation Set the impedance switch to the HI position as shipped Connect the GREEN cable lead and the shield to the amplifier chas sis ground The WHITE cable lead is the hot conductor Balanced line low impedance operation Set the impedance switch to the LO position Connect the shield to the amplifier chassis ground The WHITE and GREEN ca ble leads are the h...

Page 5: ...o microphone inputs rated at 19 to 300 ohms and High for con nection to high impedance microphone inputs Sensitivity at 1kHz open circuit voltage dependent on impedance setting LOW 57 5 dB 1 3 mV HIGH 38 5 dB 12 mV Switch Press to Talk Switch lockable for microphone and an external relay or control circuit Microphone circuit normally shorted in both high and low impedance 1 ...

Page 6: ...ration Cartridge Shock Mount Internal rubber vibration isolator Cable 2 1 m 7 ft four conductor two conductors shielded non detachable Housing Two tone gray ARMO DUR with dull chrome plated steel screen Weight 736 g 1 lb 10 oz 1 Pa 94 dB SPL Typical Polar Pattern Typical Frequency Response 1 ...

Page 7: ...levant European directives and is eligible for CE marking The CE Declaration of Conformity can be obtained from www shure com europe compliance Authorized European representative Shure Europe GmbH Headquarters Europe Middle East Africa Department EMEA Approval Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 7262 92 49 0 Fax 49 7262 92 49 11 4 Email info shure de ...

Reviews: