Electrical
7
5982 0409
Figure 9B: Pump is shipped from factory set for
115-volt operation (above).To change to 230-volt
operation, slide switch to display ‘230’ (below).
Figure 9A: Remove cover from capacitor box to
reach voltage change slide switch.
Figure 9C: Slide switch set for 230-volt operation.
CHECK VOLTAGE SETTING.
1.
Turn off power to the pump!
2. Determine if the circuit for the pump is 115 or
230 volts.
3. A qualified person must install electrical wiring.
4. The voltage switch is factory set to 115 volts. If you
have 115 volt service, do not change the selection.
1/2 HP motors are preset at the factory for 115 volts.
5. To change the voltage (if necessary), remove the
motor capacitor cover and slide the switch fully to
the correct voltage.
6. Reinstall the cover.
Do Not Turn On Power Yet!
CONNECT POWER SUPPLY WIRING
TO PRESSURE SWITCH
1. Remove the pressure switch cover.
2. Attach power and ground wires to the pressure
switch as indicated.
3. Reinstall the cover.
Do Not Turn On Power Yet!
Motor
Capacitor
Cover
Press
u
re
S
w
itch
(Cover Removed)
Gro
u
nd Wire
Connection
Po
w
er
S
u
pply
Connections
Figure 8: Connect power supply wires to pressure
switch as shown.
Disconnect power before working on pump, motor, pressure switch, or wiring.
Never wire a 115 volt motor to a 230 volt line.
For parts or assistance, call SHUR-DRI Customer Service at
1-800-535-4950