SHOWVEN
Creeper AQ mini Low Fog Generator USER MANUAL -4-
First Line: DMX address and Fan Speed, “:” blinks when there is DMX in signal.
Second Line: Shows machine core temperature and Fog Volume. The machine ready for
operate when temperature value close to 100.
Press “MENU” switch through setup menu.
b) Main Interface
c) Error Information
DMX: 1
FAN: 30
T: 100%
FOG: 80%
Error information
Explanation
E2 Temp. Sensor
Temp. Sensor Malfunction
E3 Water Sensor
Low water level of Inner Water Tank, system is pumping water
to inner water tank or liquid level sensor malfunction.
E5 Temp. Over
Circuit board malfunction
E6 Heat Fail
Heater broken or circuit board malfunction.
d) Setting Menu
Items
Explanation
DMX Address
DMX address setup
Interval Set
Set fog output interval
Fog Volume Output
Fog output volume setup
Fan Speed
Value
1~512
5-600s
1-100%
Duration Set
Set fog output duration
5-600s
1-100%
Fan speed setup
Wireless Set
Wireless function set
Auto Pump
When it is ON, machine will pump water from
exterior water tank to inner tank, and stops
when the inner tank filled up. Please turn it to
OFF when not use exterior water tank.
ON / OFF
ON / OFF
Language
Language switch
中文
/English
Sensor Disp.
Generate fog:
2, Stop: 0
Shows the number of working No.of ultrasound
head, display only.