background image

2

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

BEFORE YOUR INITIAL START-UP!

SAFETY INSTRUCTIONS

Every person involved with the installation, operation and maintenance of this device have to:

-

 be 

qualified

-

 

follow  the instructions of this manual

Before your initial start-up, please make sure that there is no damage caused by transportation. Should
there be any, consult your dealer and do not use the device.

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow
the safety instructions and warning notes written in this manual.

Please consider that damages caused by manual modifications to the device are not subject to warranty.

This device contains no user-serviceable parts. Refer servicing to qualified technicians only.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of
this manual or any unauthorized modification to the device.

  Never let the power-cord come into contact with other cables! Handle the power-cord and all

connections with the mains with particular caution!

  Never remove warning or informative labels from the unit.

  Never use anything to cover the ground contact.

  Never aim the output nozzle directly at people.

  Never aim the output nozzle at open flames.

  Never add flammable liquids of any kind (oil, gas, perfume) to the fog liquid.

  Never drink fog liquid.  If it is ingested, call a doctor immediately.  If fog liquid comes in contact with

skin or eyes, rinse thoroughly with water.

  Never lock smoke-filled rooms. Risk : panic among the locked persons!

  Never smoke permanently! The smoke must only be used for a short period -

  Do not insert objects into air vents.

  Do not open the device and do not modify the device.

  Do not connect this device to a dimmerpack.

  Do not switch the device on and off in short intervals, as this would reduce the device’s life.

  Do not touch the fogger output bare-handed during its operation (output becomes very hot).

  Do not shake the device. Avoid brute force when installing or operating the device.

CAUTION!

Keep this device away from rain and moisture!

Unplug mains lead before filling the tank!

CAUTION! Be careful with your operations.

With a dangerous voltage you can suffer

a dangerous electric shock when touching the wires!

Summary of Contents for Z-1020

Page 1: ...Z 1020 ORDERCODE 60677...

Page 2: ...rely on Antari for more excellent products We design and manufacture professional equipment for the entertainment industry New products are being launched regularly We work hard to keep you our custo...

Page 3: ...s Operating Determinations Description Features Overview Backside Installation Installing the fogger Set Up and Operation Procedure Optional Remote control operation Z 40 Controls DMX Setting DMX Dips...

Page 4: ...wer cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never aim the output nozzle...

Page 5: ...ained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to deadly electrical shocks If the external cable is damaged it has to be replaced by a qual...

Page 6: ...bient temperature ta 45 C must never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 45 C If this device is operated in any other way than the one described in this...

Page 7: ...og output min 285m3 Tank Capacity 2 5L Fluid Consumption Rate 24 Min L 100 Output 1 DMX channel Included Z 10 Remote Control Cable length 10m Optional Remotes Z 40 Timer Remote control Ordercode 60690...

Page 8: ...6 Backside 7 4 5 6 8 9 Fig 2 4 ON OFF 5 Remote control input 6 IEC Connector Fuse 7 DMX OUT 8 Dip Switches 9 DMX IN...

Page 9: ...do not allow the unit to have more than a 15 degree angle of inclination Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subje...

Page 10: ...100X B 200 B 100X B 200 Z 40 Controls Its two controls 1 2 knobs allow the operator to customize fog machine functions by adjusting output duration and interval 1 Adjust the duration of each fog emiss...

Page 11: ...g used by lighting and effects operator If Channel A has a value from 0 to 128 the unit is OFF Between the values 129 to 255 the volume of fog output is at maximum output Note In the example above if...

Page 12: ...s on each unit Example 1 If you want to give a Z 1020 DMX address133 you first have to find the number 133 in the DMX Chart 2 Then look at the left side Dip Switches 1 5 horizontally from 133 In the T...

Page 13: ...6 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 1...

Page 14: ...Notes All fog machines develop condensation around the output nozzle Because this may result in some moisture accumulation on the surface below the output nozzle consider this condensation when instal...

Page 15: ...min Tank Capacity 2 5L Fluid Consumption Rate 24 Min L 100 Output 1 DMX channel Dimensions 370x295x135mm Weight 9 7 kg Included Z 10 Remote Control Cable length 10m Optional Remotes Z 40 Timer Remote...

Page 16: ...2006 Showtec...