background image

7

Installation

Installing the Fogger

Remove all packing materials from the fog machine. Check that all foam and plastic padding is removed,
especially in the nozzle area.
Fill with Fog Liquid (ordercode 60603) or other high-quality water-based fog fluid. Any other types of fluid
can damage the unit. Be careful not to exceed the maximum fluid level. 

DO NOT OVERFILL

.

When filled, place cap back on liquid tank.
Firmly attach the remote control cable to the proper input on the rear of the machine
The unit can also be operated at floor level or sitting on any regular surface as well.
If the unit is to be mounted using the bracket, it is important that the fog does not shoot directly at any one’s
face. Therefore, do not point the nozzle in a direction that will aim directly at a person.
Whatever installation method you choose, do not allow the unit to have more than a 15 degree angle of
inclination.

Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.

Set Up and Operation

Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.

Pay Attention !!

 

Always monitor tank fluid level as you are fogging.
Running a fog machine with no fluid can permanently damage the unit.

Procedure :

1.

 Plug power cord into a grounded electrical outlet. Turn power switch on rear of unit to “ON” .

    Warm-up is complete when green LED lights up on remote unit.

2.

 To emit fog, press the button on the remote and hold for the desired length of time.

3.

 The remote unit’s lamp will cycle on and off as the machine re-heats to the proper operating temperature.

4.

 For further information on operating your Antari Fog Machine, see Optional Remote Control Operation.

Summary of Contents for Z-1020

Page 1: ...Z 1020 ORDERCODE 60677...

Page 2: ...rely on Antari for more excellent products We design and manufacture professional equipment for the entertainment industry New products are being launched regularly We work hard to keep you our custo...

Page 3: ...s Operating Determinations Description Features Overview Backside Installation Installing the fogger Set Up and Operation Procedure Optional Remote control operation Z 40 Controls DMX Setting DMX Dips...

Page 4: ...wer cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never aim the output nozzle...

Page 5: ...ained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to deadly electrical shocks If the external cable is damaged it has to be replaced by a qual...

Page 6: ...bient temperature ta 45 C must never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 45 C If this device is operated in any other way than the one described in this...

Page 7: ...og output min 285m3 Tank Capacity 2 5L Fluid Consumption Rate 24 Min L 100 Output 1 DMX channel Included Z 10 Remote Control Cable length 10m Optional Remotes Z 40 Timer Remote control Ordercode 60690...

Page 8: ...6 Backside 7 4 5 6 8 9 Fig 2 4 ON OFF 5 Remote control input 6 IEC Connector Fuse 7 DMX OUT 8 Dip Switches 9 DMX IN...

Page 9: ...do not allow the unit to have more than a 15 degree angle of inclination Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subje...

Page 10: ...100X B 200 B 100X B 200 Z 40 Controls Its two controls 1 2 knobs allow the operator to customize fog machine functions by adjusting output duration and interval 1 Adjust the duration of each fog emiss...

Page 11: ...g used by lighting and effects operator If Channel A has a value from 0 to 128 the unit is OFF Between the values 129 to 255 the volume of fog output is at maximum output Note In the example above if...

Page 12: ...s on each unit Example 1 If you want to give a Z 1020 DMX address133 you first have to find the number 133 in the DMX Chart 2 Then look at the left side Dip Switches 1 5 horizontally from 133 In the T...

Page 13: ...6 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 1...

Page 14: ...Notes All fog machines develop condensation around the output nozzle Because this may result in some moisture accumulation on the surface below the output nozzle consider this condensation when instal...

Page 15: ...min Tank Capacity 2 5L Fluid Consumption Rate 24 Min L 100 Output 1 DMX channel Dimensions 370x295x135mm Weight 9 7 kg Included Z 10 Remote Control Cable length 10m Optional Remotes Z 40 Timer Remote...

Page 16: ...2006 Showtec...