17 

   

 

Ordercode: 61133 

WTF-FZ1500 1500W DMX Fazer 

No Response to DMX 

Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card malfunction. 
01)

 

Check the DMX setting. Make sure that DMX addresses are correct. 

02)

 

Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. 
Try your DMX control again. 

03)

 

Determine whether the controller or light effect is at fault. Does the controller operate properly with 
other DMX products? If not, take the controller in for repair. If so, take the DMX cable and the light 
effect to a qualified technician. 

 
Problem 

Probable cause(s) 

Remedy 

One or more fixtures 
do not function at 
all. 

No power to the fixture. 

 

Check if power is switched on and 
cables are plugged in. 

Circuit breaker is active. 

 

Reset the circuit breaker. 

Fixtures reset 
correctly, but all 
respond erratically 
or not at all to the 
controller. 

The controller is not connected. 

 

Connect controller. 

3-pin XLR Out of the controller does 
not match XLR In of the first fixture 
on the link (i.e. signal is reversed). 

 

Install a phase reversing cable 
between the controller and the first 
fixture on the link. 

Fixtures reset 
correctly, but some 
respond erratically 
or not at all to the 
controller. 

Poor data quality. 

 

Check data quality. If much lower than 
100 percent, the problem may be a 
bad data link connection, poor quality 
or broken cables, missing termination 
plug, or a defective fixture disturbing 
the link. 

Bad data link connection. 

 

Inspect connections and cables. 
Correct poor connections. Repair or 
replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

 

Insert termination plug in output jack of 
the last fixture on the link. 

Incorrect addressing of the fixtures.  ●

 

Check address setting. 

One of the fixtures is defective and 
disturbs data transmission on the 
link. 

 

Bypass one fixture at a time until 
normal operation is regained: unplug 
both connectors and connect them 
directly together. 

 

Have the defective fixture serviced by 
a qualified technician. 

3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

 

Install a phase-reversing cable 
between the fixtures or swap pin 2 and 
3 in the fixture, that behaves erratically. 

No fog output. 

Fixture is too hot. 

 

Allow fixture to cool. 

 

Make sure air vents are not blocked. 

 

Turn up the air conditioning. 

The device is damaged. 

 

Disconnect fixture and return to your 
dealer. 

The power supply settings do not 
match local AC voltage and 
frequency. 

 

Disconnect fixture. Check settings and 
correct if necessary. 

 

 

Summary of Contents for WTF-F1000

Page 1: ...WTF FZ1500 1500W DMX Fazer V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 61133 MANUAL ENGLISH...

Page 2: ...Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 12 1 Interval Time 13 2 Duration Time 13 3 Timer Output 13 4 Volume Output 13...

Page 3: ...our shipment includes WTF FZ1500 1500W DMX Fazer with a power cable 1 8 m 1 x tank hose User manual Safety Instructions Every person involved with the installation operation and maintenance of this de...

Page 4: ...this unit without liquid can cause damage to the pump and the heater Always allow free air space of at least 50 cm around the sides and top of the unit Always allow free air space of at least 50 cm a...

Page 5: ...on use completely disconnect from power source via breaker or by unplugging The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way tha...

Page 6: ...stion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02...

Page 7: ...Heater 1450 W Output 6000 cu ft min Heating time 1 5 minutes Tank capacity 5 L Liquid consumption 5 1 ml min full output Control modes Manual DMX 512 DMX mode 1 1 2 channels Color Black Housing Metal...

Page 8: ...eration Using a damaged or an improperly installed machine can lead to death serious injury or property damage Always inspect the machine thoroughly before operation Missing or obscured safety symbols...

Page 9: ...ap and attach it firmly to the liquid input 09 See Fig 03 03 Replace the cap and tighten it around the liquid input 09 See Fig 04 Fig 02 Fig 03 Fig 04 04 Attach the other end of the tank hose to the f...

Page 10: ...ion about Manual mode Multiple WTFs DMX Control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Plug the end of the electric mains power cord...

Page 11: ...ruct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cable...

Page 12: ...Therefore the DMX address of the first WTF should be 1 001 the DMX address of the second WTF should be 1 2 3 003 the DMX address of the third WTF should be 3 2 5 005 etc Please make sure that you do n...

Page 13: ...into a grounded electrical outlet The machine will now re heat to the proper operating temperature Once the proper temperature has been reached the display will show the main menu Interval Time Durat...

Page 14: ...this menu you can set the output volume in Volume mode 01 Press the MENU button until the display shows VOLUME 02 Press the UP DOWN buttons to set the output volume The adjustment range is 1 100 from...

Page 15: ...Mode If you wish to use the WTF in Manual mode unplug the DMX cable Manual mode will not work if the DMX cable is connected 1 Timer Mode In this menu you can set Timer mode 01 Set the interval and du...

Page 16: ...Always close the fog liquid tank immediately after adding the fog liquid to the tank Performance Note Fog machines develop condensation around the output nozzle Because this may result in moisture ac...

Page 17: ...it operates properly do not carry out following steps If the WTF does not operate properly refer servicing to a technician 01 If you experience low output or no output at all unplug immediately 02 Che...

Page 18: ...set correctly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor qualit...

Page 19: ...de 1 1 2 channels Color Black Housing Metal flame retardant plastic Data connection 3 pin 5 pin XLR IN OUT Power connection Fixed Schuko power cable 1 8 m IP rating IP20 Dimensions 438 x 395 x 260 mm...

Page 20: ...2020 Showtec...

Reviews: