background image

 

  

 

 

   

 

Ordercode: 42278 

White-PIX 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 
meter. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40° C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 

Rigging 

Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the projector is lowered from the ceiling or high joists, professional trussing systems have to be used. 

 

Use a clamp to mount the projector, with the mounting bracket, to the trussing system. 

 

The projector must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 
safety cable. 

 

When rigging, derigging or servicing the projector, always make sure, that the area below the 
installation site is secured and that there are not any unauthorized people around. 

 

Improper installation can cause serious injuries and/or damage of property! 

 

 

Summary of Contents for White-PIX V1

Page 1: ...White PIX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42278 MANUAL ENGLISH ...

Page 2: ... Control 11 Multiple PIX devices ArtNet KlingNet Control 12 Fixture Linking 13 Data Cabling 13 Control Panel 14 Control Mode 14 DMX Addressing 14 Menu Overview 15 Main Menu Options 15 1 Auto Mode 16 2 DMX Channels 16 3 DMX Address 16 4 Software Information 17 5 Network Settings 17 6 Master Slave Mode 17 DMX Channels 18 6 channels 18 25 channels 19 Connecting to a Network 20 KlingNet settings 20 Ar...

Page 3: ...s the dominant factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving the lifespan is of higher priority place care in providing for lower operational temperatures T...

Page 4: ...e of at least 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure t...

Page 5: ...ger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to m...

Page 6: ...color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the device is always properly connected to the earth Improper installation can cause serious injuries and or damage of property ...

Page 7: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merch...

Page 8: ...lumen Color temperature 3200K Control Protocol DMX 512 ArtNet KlingNet Built in programs 30 programs DMX channels 6 and 25 channels Onboard LCD display for easy setup Connectors Blue White power connector and 3 pin XLR RJ45 IN OUT Cooling Convection Dimmer 0 100 Strobe 0 30Hz Field angle 8º Pixels 5H x 5V Pixel pitch 60 mm Housing Die cast aluminium and flame retardant plastic IP rating IP20 Fuse ...

Page 9: ...T 08 3 pin DMX signal connector IN 09 Fuse F5AL 250V 10 Blue White power connector 100 240V IN 11 LCD display menu buttons Installation Remove all packing materials from the White PIX Check if all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or s...

Page 10: ...l Installation of White PIX It is possible to install multiple White PIX devices by attaching them to each other in a vertical position Follow the instructions below to carry out the installation process Fig 03 01 Loosen the mounting screws on the White PIX 1 and release the mounting rail 02 Insert the mounting rail in the slot on the White PIX 2 03 Tighten the mounting screws to secure both White...

Page 11: ...le PIX device Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the White PIX The pins 01 Earth 02 Signal 03 Signal 03 Link the units as shown in fig 04 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second...

Page 12: ...the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the whole system ...

Page 13: ...ect the first unit s RJ45 out socket with the second unit s in socket using a CAT 5 CAT 6 signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the ...

Page 14: ... own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X type data cable XLR M 3 pin XLR F 3 p...

Page 15: ... the third White PIX should be 26 25 51 051 etc Please be sure that you do not have any overlapping channels in order to control each White PIX correctly If two or more PIX devices are addressed similarly they will work similarly Controlling After having addressed all White PIX fixtures you may now start operating these via your lighting controller Note After switching on the White PIX will automa...

Page 16: ...15 Ordercode 42278 White PIX Menu Overview Main Menu Options Auto Mode DMX channels DMX address Software information Network settings Master Slave Mode ...

Page 17: ...ween the available programs You can choose between 29 programs and Mix all the built in programs will be displayed in a sequence 09 Press the ENTER button to save changes 2 DMX Channels With this menu you can set the desired channel mode 01 Press the UP DOWN buttons until the display shows 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to choose between the 2 DMX channel m...

Page 18: ...n the following 3 options IP address Subnet mask Universe 04 Once you have chosen one of the options listed above press the ENTER button to proceed to edition mode 05 Press the UP DOWN buttons to choose the piece of the IP address Subnet mask Universe which needs to be adjusted and which is indicated by the bracket 06 Press the ENTER button to confirm your choice 07 Press the UP DOWN buttons to ad...

Page 19: ...m 3 64 79 Program 4 80 95 Program 5 96 111 Program 6 112 127 Program 7 128 143 Program 8 144 159 Program 9 160 175 Program 10 176 191 Program 11 192 207 Program 12 208 223 Program 13 224 239 Program 14 240 255 Program 15 Channel 5 Built in programs 16 30 Dimmer must be open and CH3 must be set to 0 0 15 Not functional 16 31 Program 1 32 47 Program 2 48 63 Program 3 64 79 Program 4 80 95 Program 5 ...

Page 20: ... 0 100 Channel 5 LED 5 0 255 Gradual adjustment LED from 0 100 Channel 6 LED 6 0 255 Gradual adjustment LED from 0 100 Channel 7 LED 7 0 255 Gradual adjustment LED from 0 100 Channel 8 LED 8 0 255 Gradual adjustment LED from 0 100 Channel 9 LED 9 0 255 Gradual adjustment LED from 0 100 Channel 23 LED 23 0 255 Gradual adjustment LED from 0 100 Channel 24 LED 24 0 255 Gradual adjustment LED from 0 1...

Page 21: ...ake sure that all the fixtures in the network have a unique IP address 06 If you want to connect more than one fixture follow the example below Example The White PIX 25 channel mode 01 Make sure that each connected White PIX has a unique IP address 02 Make sure that the subnet mask on each device is set to 255 0 0 0 03 Set the universe of the first White PIX to 1 04 Set the first PIX device s DMX ...

Page 22: ...red as follows Fig 08 Software for controlling In combination with Arkaos or DMT Software you are able to play videos over the White PIX pixelmapping You only have to connect all the PIX devices and run your software 50180 Arkaos LED Master An all in one solution to run LED light shows for everyone Originally designed around KlingNet this fast and easy application will take your LED show to the ne...

Page 23: ...ions with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow the directions below to do so 01 Unplug the unit from electric power source 02 In...

Page 24: ... to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug ...

Page 25: ...ature 3200K Pixels 5H x 5V Pixel pitch 60 mm Field angle 8 Dimmer 0 100 Strobe 0 30Hz Housing Die cast aluminium metal bracket Control protocol DMX 512 ArtNet KlingNet DMX control via standard DMX controller Onboard LCD display for easy setup Control Auto Master Slave DMX 512 ArtNet Klingnet IP rating IP20 Connections Dedicated Blue White to IEC Data connector Cooling Convection Max ambient temper...

Page 26: ...25 Ordercode 42278 White PIX Dimensions ...

Page 27: ...26 Ordercode 42278 White PIX Notes ...

Page 28: ... 2015 Showtec ...