background image

11

Maintenance

The operator has to make sure that safety-relating and machine-technical installations are to be inspected
by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be inspected
by a skilled person once a year.

The following points have to be considered during the inspection:

1. 

All screws used for installing the device or parts of the device have to be tightly connected and must

    not be corroded.

2. 

There may not be any deformations on housings, fixations and installation spots.

3. 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing.

4. 

The electric power supply cables must not show any damages or material fatigue.

The Showtec Sunstrip Active requires almost no maintenance. However, you should keep the unit clean.

Otherwise, the fixture’s light-output will be significantly reduced. 

Disconnect the mains power supply, and

then wipe the cover with a damp cloth. Do not immerse in liquid. Do not use alcohol or solvents.

The device will require monthly cleaning with a soft brush, as smoke-fluid tends to build up residues,
reducing the light-output very quickly.

Please clean internal components once a year with a light brush and vacuum cleaner.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections with a
damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.

Changing the Lamp

1.

 Disconnect mains power supply, and allow 15 minutes to cool down. Loosen the 4 screws on the front of

    the housing.

2.

 Gently remove the metal housing.

3.

 Follow directions for installing a new lamp, page 6.

Replacing a Fuse

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the fuse
burns out, the product will not function whatsoever. If this happens, 

follow the directions below to do so.

1.

 Unplug the unit from electric power source.

2.

 Insert a flat-head screwdriver into the slot in the fuse cover. Turn the screwdriver to the left, at the same

    time gently push a bit (Turn and Push). The fuse will come out.

3.

 Remove the used fuse. If brown or unclear, it is burned out.

4.

 Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to

    use a fuse of the same type and specification. See the product specification label for details.

Summary of Contents for Sunstrip Active DMX

Page 1: ...Sunstrip Active DMX ORDERCODE 30710...

Page 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep y...

Page 3: ...Operating Determinations Rigging Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One Sunstrip Active Multiple Sunstrip Active s Operation Modes DMX Mo...

Page 4: ...ticular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or...

Page 5: ...ice fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service For adult use only The device...

Page 6: ...winging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the Sunstrip always make s...

Page 7: ...and output Mounting Floor brackets included Built in Dimmerpack 10x Showtec Lamp 240V 75W GU10 82382 Included Fuse T6 3A 250V Overview Fig 1 1 10x Showtec Lamp 240V 75W GU10 82382 Fig 2 2 Power Thru...

Page 8: ...higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the fr...

Page 9: ...Sunstrip Active 1 Fasten the effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Sunstrip Active Leave at least 1 meter on all sides for air circulation 2 Use a 3...

Page 10: ...ts 01 02 05 or 10 in the LED Display You cannot use the MENU Button to select the Channel Mode unless you have selected the DMX Operation Mode as in Step 1 Setting the Channel Value Once you have acti...

Page 11: ...the Chase Mode has been activated If the Chase Mode has been activated the Chase program Mode starts and is the Default setting Setting the Chase Program Once you have activated the Chase Mode you can...

Page 12: ...lay shows d followed by 2 digits Setting the Intensity Use the UP or DOWN button to change the setting from 00 100 A value of 000 means the weakest output intensity and a value of 100 means the highes...

Page 13: ...with a soft brush as smoke fluid tends to build up residues reducing the light output very quickly Please clean internal components once a year with a light brush and vacuum cleaner Keep connections c...

Page 14: ...lamp Replace the old lamp with a new one with the same specifications See page 6 for replacing lamps 3 The fuse Replace the fuse See page 11 for replacing the fuse No Response to DMX Response Suspect...

Page 15: ...ct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing...

Page 16: ...nal output 3 pin XLR female Lamp Allowed lamp models Showtec Lamp 240V 75W GU10 500 hr ordercode 82382 Electro mechanical effects DMX control via standard DMX controller Max ambient temperature ta 55...

Page 17: ...2005 Showtec...