background image

 

Control Panel 

When the indicator light is on, means the Inferno is working 

 
 
 
 
 
 
 
 
 
     
 
 
 
 

 

 

 

 

 

 

 

 

 

Fig. 5

 

 

 

A.

 Power LED   

 

D.

 [MENU] Button 

 

G.

 [ENTER] Button 

B.

 Display 

 

 

E.

 Up Button   

 

H.

 Sound LED 

C.

 DMX LED 

 

 

F.

 Down Button 

 

 

DMX Control Mode 

The fixtures are individually addressed           

        

       on a data-link and connected to the controller.  

The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address the next time.)

 

 

DMX Addressing

 

The control panel on the front side of the Inferno allows you to assign the DMX fixture address, which is the 
first channel from which the Inferno will respond to the controller. 
Please note when you use the controller, the unit has 

1

 channel. 

When using multiple Inferno’s, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Inferno should be 

1 (A001)

; the DMX address of the second Inferno 

should be 

1+1=2 (A002

); the DMX address of the third Inferno should be 

2+1=3 (A003)

, etc. Please, be 

sure that you don’t have any overlapping channels in order to control each Inferno correctly. 
If two or more Inferno’s are addressed similarly, they will work similarly.

 

For address settings, please refer to the instructions under ”Addressing’ (menu 

)

 

 

Controlling: 

After having addressed all Inferno fixtures, you may now start operating these via your lighting controller.

 

Note:

 After switching on, the Inferno will automatically detect whether DMX 512 data is received or not. 

If 

there is 

no data received at the DMX-input, the “

LED

 “ on the control panel will not flash.

 

The problem may be:

 

- The XLR cable from the controller is not connected with the input of the Inferno.

 

- The controller is switched off or defective, the cable or connector is detective, or the signal wires are    
  swapped in the input connector. 

 
Note: 

It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link. 
 
For synchronous operation of multiple fixtures the fixtures must all be connected on a data-link and be 
given the same DMX address.  
Note: Disconnect the fixtures from the DMX controller before master/slave operating, otherwise data 
collisions can occur and the fixtures will not work properly! 

Summary of Contents for Starzone Inferno DMX

Page 1: ...Starzone Inferno DMX ORDERCODE 31323...

Page 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Page 3: ...erating Determinations Rigging Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One Inferno Multiple Inferno s DMX Protocol DMX Channels Control Mode DM...

Page 4: ...unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a...

Page 5: ...Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service For adult use only...

Page 6: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Page 7: ...ne mode DMX 512 1channels Variable direction and variable speed Flowing Fire Effect Fixed Colour LCD Display Variable focus Lamp EFP GZ6 35 12V 100W not included Ordercode 80810 80810O 80810S 82399 82...

Page 8: ...6 Backside 4 5 6 Fig 2 4 DMX signal connector OUT 5 DMX signal connector IN 6 IEC Power connector Fuse...

Page 9: ...rranty Procedure 1 Loosen the 6 screws on the back of the housing 2 Gently remove the plastic housing 3 Read lamp instructions Do not touch the lamp bulb glass See Figure 3 Oil on hands shortens the l...

Page 10: ...figure 4 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 4 Supply electric power Plug elect...

Page 11: ...any overlapping channels in order to control each Inferno correctly If two or more Inferno s are addressed similarly they will work similarly For address settings please refer to the instructions unde...

Page 12: ...ohol or solvents The front PC lens will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly The cooling fans and the internal lenses should be clea...

Page 13: ...ation Model Showtec Inferno Voltage 240V 50Hz CE Fuse F1A 250V Dimensions 340x350x280mm LxWxH Weight 3 45 kg Lamp Allowed lamp models Philips EFP GZ6 35 12V 100W 50 hr 750 Lumen ordercode 80810 Osram...

Page 14: ......

Reviews: