background image

 

  

 

 

   

 

Ordercode: 43551 

Spectral PC 600Z IP 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
agreed otherwise in writing. 
Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of 
the invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement from which the obligation is resulting.  
 

 

Summary of Contents for Spectral PC 600Z IP

Page 1: ...Spectral PC 600Z IP V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43551 MANUAL ENGLISH ...

Page 2: ... DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 Static Colors 14 2 DMX Address 15 3 Built in programs 15 4 Master Slave Mode 15 5 Zoom Mode 15 6 Personality DMX channel modes 16 7 Edit Mode 16 7 1 How to make your own custom program 17 8 Settings 17 8 1 Upload 17 8 2 Reset 17 8 3 Color 18 8 4 Dimmer 18 8 5 DMX Error 18 8 6 PWM rate 18 8 7 Color temperature 18 9 Safety lock 18 10 Calibra...

Page 3: ...owtec Spectral PC 600Z IP Safety cable Schuko to IP rated power cable 1 3 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fulle...

Page 4: ... firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handl...

Page 5: ...it burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussi...

Page 6: ... the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the device is always properly connected to the earth Improper installation can cause serious injuries an...

Page 7: ... number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of ...

Page 8: ... protocol DMX 512 DMX personalities 9 9 12 17 channels LCD display Dimmer 0 100 Strobe 0 20Hz Beam Angle 4 5 45 Control Static Colors Auto Master Slave DMX 512 Housing Die cast aluminum Connections IP rated power connector IN OUT 3 pin XLR IN OUT Cooling Convection IP Rating IP65 Dimensions 243 x 240 x 300 mm LxWxH Weight 5 8 kg Frontside Fig 01 01 Color frame retaining clip 02 Multichip RGBW LED ...

Page 9: ...onnect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply...

Page 10: ... cord into a proper electric power supply socket 06 When the Spectral is not connected with a DMX cable it functions as a stand alone device Please see page 15 for more information about the built in programs Multiple Spectrals Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the Spectra...

Page 11: ... first unit s DMX in socket using a DMX cable Connect the first unit s out socket with the second unit s in socket using a DMX cable Link the second third and fourth units 05 Supply electric power Plug electric mains power cords into each unit s special IP rated power IN socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do...

Page 12: ...ures on a power link 240V 20 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DA...

Page 13: ...ress of the third Spectral should be 18 17 35 035 etc Please be sure that you do not have any overlapping channels in order to control each Spectral correctly If two or more Spectrals are addressed similarly they will work similarly Controlling After having addressed all Spectral fixtures you may now start operating these via your lighting controller Note After switching on the Spectral will autom...

Page 14: ...13 Ordercode 43551 Spectral PC 600Z IP Menu Overview ...

Page 15: ... 03 Press the UP DOWN buttons to toggle between the static colors RED GREEN BLUE WHITE ZOOM and STROBE 04 Once you have chosen the desired color press the ENTER button to enter edition menu 05 Press the UP DOWN buttons to adjust the color intensity The adjustment range is between 0 255 from dark to brightest 06 Press the ENTER button to proceed to ZOOM Press the UP DOWN buttons to set the zoom eff...

Page 16: ...4 Press the ENTER button to select the desired built in program 05 If you have chosen one of the programs AUTO1 AUTO10 press the ENTER button to proceed to the program speed settings 06 Press the UP DOWN buttons to set the program speed The adjustment range is between 0 255 from slow to fast 07 The device will now run the desired built in program 4 Master Slave Mode With this menu you can set the ...

Page 17: ... custom program PROGRAM1 PROGRAM 10 04 Each custom program has 30 scenes which can be edited Press the UP DOWN buttons to select the desired scene 05 Press the ENTER button to enter the scene settings 06 Press the UP DOWN buttons to toggle between RED GREEN BLUE WHITE ZOOM STROBE TIME and FADE options 07 If you have chosen RED GREEN BLUE or WHITE press the ENTER button to open the menu 08 Press th...

Page 18: ...nd press the ENTER button to confirm 04 Press the UP DOWN buttons to toggle between the following menus Upload Reset Color Dimmer DMX Error PWM Full_Power CCT 8 1 Upload With this menu you can export current programs from the master device to the connected slave devices 01 While in SETTING menu press the UP DOWN buttons to choose UPLOAD 02 Press the ENTER button to open the menu 03 Insert the pass...

Page 19: ...ess the UP DOWN buttons to toggle between the 2 options BLACK and SAVE 04 If you have chosen BLACK the Spectral will black the output out in case of a DMX signal error 05 If you have chosen SAVE the Spectral will fall back on the last working DMX signal which will ensure undisrupted performance 8 6 PWM rate With this menu you can set the PWM rate 01 While in SETTING menu press the UP DOWN buttons ...

Page 20: ...utton to open the submenu 04 Press the ENTER button to toggle between RED GREEN BLUE and WHITE 05 Press the UP DOWN buttons to increase decrease the intensity of the chosen color The adjustment range of each color is between 0 255 from OFF to FULL ON 10 2 RGBW calibration With this menu you can adjust the temperature of the white color by means of RGB colors 01 If you have chosen RGBW press the EN...

Page 21: ...e 5 4000K 111 130 White 6 4200K 131 150 White 7 4500K 151 170 White 8 5600K 171 190 White 9 6000K 191 210 White 10 6500K 211 230 White 11 7200K 231 255 White 12 8000K Channel 6 Strobe Dimmer must be open 0 9 Not functional 10 99 Strobe flash frequency from slow to fast 100 109 Not functional 110 179 Pulse strobe from slow to fast 180 189 Not functional 190 255 Random strobe from slow to fast Chann...

Page 22: ... adjustment White from 0 100 Channel 6 Strobe Dimmer must be open 0 9 Not functional 10 99 Strobe flash frequency from slow to fast 100 109 Not functional 110 179 Pulse strobe from slow to fast 180 189 Not functional 190 255 Random strobe from slow to fast Channel 7 Zoom 0 255 Zoom adjustment from small to big Channel 8 Zoom functions 0 200 Not functional 201 220 Zoom reset 221 255 Not functional ...

Page 23: ...en 100 Blue 0 51 70 Red 0 Green 100 Blue Up 71 90 Red 0 Green Down Blue 100 91 110 Red Up Green 0 Blue 100 111 130 Red 100 Green 0 Blue Down 131 150 Red 100 Green Up Blue Up 151 170 Red Down Green Down Blue 100 171 195 Red 100 Green 100 Blue 100 White 100 196 200 White 1 2700K 201 205 White 2 3000K 206 210 White 3 3200K 211 215 White 4 3500K 216 220 White 5 4000K 221 225 White 6 4200K 226 230 Whit...

Page 24: ...am 5 191 200 Program 6 201 210 Program 7 211 220 Program 8 221 230 Program 9 231 255 Program 10 Channel 9 Auto speed CH8 must be set between 41 140 0 255 Speed adjustment from slow to fast Channel 10 Zoom 0 255 Zoom adjustment from small to big Channel 11 Zoom functions 0 200 Not functional 201 220 Zoom reset 221 255 Not functional Channel 12 Dimmer speed 0 9 Preset dimmer speed from the device s ...

Page 25: ...0 Channel 8 Fine Blue Dimmer must be open 0 255 Fine adjustment Blue from 0 100 Channel 9 White Dimmer must be open 0 255 Gradual adjustment White from 0 100 Channel 10 Fine White Dimmer must be open 0 255 Fine adjustment White from 0 100 Channel 11 Macros Dimmer must be open 0 10 Not functional 11 30 Red 100 Green Up Blue 0 31 50 Red Down Green 100 Blue 0 51 70 Red 0 Green 100 Blue Up 71 90 Red 0...

Page 26: ...uto 7 111 120 Auto 8 121 130 Auto 9 131 140 Auto 10 141 150 Program 1 151 160 Program 2 161 170 Program 3 171 180 Program 4 181 190 Program 5 191 200 Program 6 201 210 Program 7 211 220 Program 8 221 230 Program 9 231 255 Program 10 Channel 14 Auto speed CH13 must be set between 41 140 0 255 Speed adjustment from slow to fast Channel 15 Zoom 0 255 Zoom adjustment from small to big Channel 16 Zoom ...

Page 27: ...ush and vacuum cleaner Keep connections clean Disconnect electric power and then wipe the DMX connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit op...

Page 28: ...k connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until no...

Page 29: ... 1 x Multichip RGBW LED Lux 2 m 19200 Beam angle 4 5 45 Dimmer 0 100 Strobe 0 20 Hz Housing Die cast aluminum DMX control via standard DMX controller Onboard LCD display for easy setup Control Static Colors Auto Master Slave DMX 512 Connections Dedicated IP rated power cable data connector Cooling Convection IP rating IP65 Max ambient temperature ta 40 C Max housing temperature tB 80 C Minimum dis...

Page 30: ...29 Ordercode 43551 Spectral PC 600Z IP Dimensions ...

Page 31: ...30 Ordercode 43551 Spectral PC 600Z IP ...

Page 32: ... 2016 Showtec ...

Reviews: