background image

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 0.5 meter. 

 

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 
 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property ! 

 

 

Rigging 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the Spectral D5000 is lowered from the ceiling or high joists, professional trussing systems have to 
be used. 

 

Use a clamp to mount the Spectral D5000, with the mounting-bracket, to the trussing system. 

 

The Spectral D5000 must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the Spectral D5000, always make sure, that the area below 
the installation place is blocked and staying in the area is forbidden.

 

 

 

The Spectral D5000 can be mounted in a hanging position (Fig. Above) or Upright (Fig. Below), using the 
support brackets. Mounting the Spectral D5000 with a clamp or any other mounting bracket is 
recommended, depending on the requirements of your application. 

 

 

The Spectral D5000 can be placed on a flat stage floor or mounted to any kind of truss by a clamp. 

 

Improper installation can cause serious damage to people and property !

 

Summary of Contents for Spectral D5000

Page 1: ...Spectral D5000 RGB IP65 ORDERCODE 43509 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...tiple Spectrals DMX Control 10 Fixture Linking 12 Data Cabling 12 Control Panel 13 DMX Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1 Personality 15 2 Master Slave Mode 15 3...

Page 4: ...EDs is significantly reduced It is estimated that a viable lifespan of 40 000 to 50 000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a high...

Page 5: ...cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the truss system The cable insert or the female part in the device m...

Page 6: ...issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Spectral D5000 is lowered from the ceiling or high joists professio...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...DMX 512 3 6 or 7 DMX channels 5 different DMX Operating modes RGB colour mixing with or without DMX controller Display LED display for auto and custom control Control DMX 512 Auto Master Slave Dimmer...

Page 9: ...Channel Description 1 Master Dimmer 2 Red 3 Green 4 Blue 5 Strobe 6 Built in Programs 7 CH Channel Description 1 Master Dimmer 2 Red 3 Green 4 Blue 5 Strobe 6 Built in Programs 7 Preset Colors Overvie...

Page 10: ...ety Eye 7 Power OUT 8 DMX signal connector OUT 4 5 6 8 Note You cannot plug a standard DMX cable directly into the connector Be sure to use the included special cable for DMX connection Female 3 pin D...

Page 11: ...lled Master Slave DMX512 3 6 or 7 Channels One Spectral Static Colors 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 When the Spectral is not...

Page 12: ...he master device you can set your desired operation Mode and all slave devices will react the same as the master device Multiple Spectrals Master Slave control Fig 3 Multiple Spectrals DMX Control 1 P...

Page 13: ...ig 4 Note Link all DMX cables before connecting electric power 5 Do not supply power before the whole system is set up and connected properly Design your show according to your DMX controller function...

Page 14: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Spectrals on a DMX data link 30 fixtures 220V 8 units may be...

Page 15: ...e you set the DMX addresses right Therefore the DMX address of the first Spectral should be 1 A001 the DMX address of the second Spectral should be 1 7 8 the DMX address of the third Spectral should b...

Page 16: ...14 Menu Overview...

Page 17: ...speed adjustable 9 Fade speed adjustable 10 Seven Color Jump speed adjustable 11 Built in Programs speed adjustable 12 Speed of the built in programs and 7 color jump 1 Personality Enter the PERSONALI...

Page 18: ...moothest Creating a static color 5 Blue 1 When you press ENTER in menu bL you can set the intensity of the blue LEDs 2 You can set the value of the blue LEDs 0 255 6 Green 1 When you press ENTER in me...

Page 19: ...can choose a variety of built in programs 2 You can choose one of the 16 built in programs 0 16 Pr00 Red Pr01 Green Pr02 Blue Pr03 Yellow Pr04 Cyan Pr05 Purple Pr06 White Pr07 Red strobe Pr08 Green s...

Page 20: ...adual adjustment Green from 0 100 Channel 4 Blue 0 255 Gradual adjustment Blue from 0 100 Channel 5 Shutter Strobe Dimmer must be open 0 14 No Function 15 255 Strobe effect from slow to fast 0 20 flas...

Page 21: ...es sec Channel 6 Built in Programs CH1 CH 2 CH 3 and CH4 must also be used when CH6 32 127 0 31 No Function 32 63 Dim Bright 64 95 Bright Dim 96 127 Dim Bright Dim 128 159 RGB gradual Color Change 160...

Page 22: ...a of Lux Y to Distance X SDC 0 004 Colors X CIE 1931 Y CIE 1931 R 0 7038 0 2960 G 0 1694 0 7518 B 0 1379 0 0444 RGB 0 2557 0 2023 Colors Formula X distance in meters Y Lux R Y 4469 8X R 0 9986 G Y 840...

Page 23: ...ning as smoke fluid tends to build up residues reducing the light output very quickly Do not immerse in liquid Keep connections clean Disconnect electric power and then wipe the DMX connections with a...

Page 24: ...again 4 If you are unable to determine the cause of the problem do not open the Spectral as this may damage the unit and the warranty will become void 5 Return the device to your Showtec dealer No Res...

Page 25: ...and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incor...

Page 26: ...0 20Hz Beam Angle 25 degrees Refreshrate 400 Hz Housing Die Cast Aluminium Powder Coat Finish Colour Black Lens Plate Tempered Glass Double bracket yoke doubles as floor stand DMX Connection Dedicate...

Page 27: ......

Reviews: