SHOWTEC Plum Flower LED Manual Download Page 16

 

14 

Replacing a Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below.

 

1.

 Unplug the unit from electric power source. 

2.

 

Insert a flat-head screwdriver into a slot in the fuse cover. Gently pry up the fuse cover

. The fuse will  

    come out. 

3.

 Remove the used fuse. If brown or unclear, it is burned out. 

4.

 Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to  

    use a fuse of the same type and specification. See the product specification label for details. 
 

Troubleshooting 

 

No Light 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps.If the light effect does not operate properly, refer servicing to a technician. 
Response: Suspect three potential problem areas: the power supply, the LEDs, the fuse. 

1.

 Power supply. Check that the unit is plugged into an appropriate power supply. 

2.

 The LEDs. Return the Plum Flower LED to your Showtec dealer. 

3.

 The fuse. Replace the fuse. See page 13 for replacing the fuse. 

 
 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 

1.

 Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.  

    Try your DMX control again. 

2.

 Determine whether the controller or light effect is at fault. Does the controller operate properly with  

    Other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light  
    effect to a qualified technician. 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Problem 

Probable cause(s) 

Remedy 

One or more fixtures 
are completely 
dead. 

No power to the fixture 

· Check that power is switched on  
  and cables are plugged in. 

Primary fuse blown. 

· Replace fuse. 

Fixtures reset 
correctly, but all 
respond erratically or 
not at all to the 
controller. 

The controller is not connected. 

· Connect controller. 

3-pin XLR Out of the controller does not 
match XLR Out of the first fixture on the 
link (i.e. signal is reversed). 

· Install a phase reversing cable  
  between the controller and the first  
  fixture on the link. 

 
 
 
 
 
 
 
 
 

 
Fixtures reset 
correctly, but some 
respond erratically or 
not at all to the 
controller. 

 
 
 
Poor data quality 

· Check data quality. If much lower than 100  
   percent, the problem may be a bad data  
   link connection, poor quality or broken  
   cables, missing termination plug, or a  
   defective fixture disturbing the link. 

 
Bad data link connection 

· Inspect connections and cables.  
  Correct poor connections. Repair or  
  replace damaged cables. 

Data link not terminated with 120 Ohm 
termination plug. 

· Insert termination plug in output jack  
  of the last fixture on the link. 

Incorrect addressing of the fixtures. 

· Check address setting. 

 
 
One of the fixtures is defective and 
disturbs data transmission on the link. 

· Bypass one fixture at a time until  
  normal operation is regained: unplug  
  both connectors and connect them  
  directly together. 

· Have the defective fixture serviced  
  by a qualified technician. 

 
3-pin XLR Out on the fixtures does not 
match (pins 2 and 3 reversed). 

· Install a phase-reversing cable 
  between the fixtures or swap pin 2  
  and 3 in the fixture, that behaves  
  erratically. 

 
No light 

The power supply settings do not match 
local AC voltage and frequency. 

· Disconnect fixture. Check settings  
  and correct if necessary. 

Summary of Contents for Plum Flower LED

Page 1: ...Plum Flower LED ORDERCODE 43052...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...ns Rigging Return Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Sound Control Mode Built in Programs Master Slave Mode DMX Mode Dipswitch...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may incl...

Page 5: ...r than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the truss sy...

Page 6: ...on yourself Always let the installation be carried out by an authorized dealer Procedure If the Plum Flower LED is lowered from the ceiling or high joists professional trussing systems have to be used...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...DMX 512 controlled Channels 7 Signal connector XLR 3 pole Male Female Power consumption 15W Mode DMX512 Stand alone and Music controlled Master Slave Sound controlled via built in microphone Fuse 1A 2...

Page 9: ...foam and plastic padding is removed Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are...

Page 10: ...all colors are lit Each time a color is added the motor will change its direction accordingly Program 4 Dipswitch 10 set to ON White Blue Amber Green Red Every single color will be added to the previ...

Page 11: ...l Dipswitch 9 should be set to ON Slave Control Dipswitch 1 should be set to ON Program 3 Master Control Dipswitch 8 9 should be set to ON Slave Control Dipswitch 1 should be set to ON Program 4 Maste...

Page 12: ...cess to link the second third and fourth units 4 Set DMX dip switches as follows See Dip Switch setting page 10 Plum Flower LED Address Value DMX Dip Switches ON Unit 1 1 Unit 2 8 Unit 3 15 Unit 4 22...

Page 13: ...hes ON Unit 5 29 1 3 4 5 Switch Value 1 1 3 4 4 8 5 16 Total sum 29 Explanation Since each unit has 7 channels each address advances 7 values See Address Value above Once address values are determined...

Page 14: ...12...

Page 15: ...loth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a d...

Page 16: ...s If not take the controller in for repair If so take the DMX cable and the light effect to a qualified technician Problem Probable cause s Remedy One or more fixtures are completely dead No power to...

Page 17: ...ave DMX 512 controlled Channels 7 Signal connector XLR 3 pole Male Female Sound controlled via built in microphone Fuse 1A 250V Dimensions LxWxH 420 x 145 x 120 mm Weight 3 kg Minimum distance Minimum...

Page 18: ......

Reviews: