13
DMX Channels
Channel 1 – Red
0-5
OFF
6-255
Red ON
Channel 2 – Green
0-5
OFF
6-255
Green ON
Channel 3 – Amber
0-5
OFF
6-255
Amber ON
Channel 4 – Blue
0-5
OFF
6-255
Blue ON
Channel 5 – White
0-5
OFF
6-255
White ON
Channel 6 – Light ON/Off, Strobe
0-5
LEDs ON
6-10
LEDs OFF
11-255
Strobe from slow to fast (1-20Hz)
Note:
For CH6 to function correctly, CH1, CH2, CH3, CH4 and/or CH5 must be set between 6-255
Channel 7 – Rotation
0-111
Clockwise rotation from fast to slow
112-143
No Rotation
144-255
Counter Clockwise rotation from slow to fast
Note:
For CH7 to function correctly, CH1, CH2, CH3, CH4 and/or CH5 must be set between 6-255
Maintenance
The Showtec Plum Flower LED requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture’s light-output will be significantly reduced.
Disconnect the mains power supply, and
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and
a soft cloth. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and
then wipe the connections with a damp cloth. Make sure connections are thoroughly dry before linking
equipment or supplying electric power.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1.
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2.
There may not be any deformations on housings, fixations and installation spots.
3.
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4.
The electric power supply cables must not show any damages or material fatigue.