Problem 

Probable cause(s) 

Remedy 

 
One or more 
fixtures are 
completely dead. 

No power to the fixture 

· Check that power is switched on  
  and cables are plugged in. 

Primary fuse blown. 

· Replace fuse. 

 

 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

· Connect controller. 

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

· Install a phase reversing cable  
  between the controller and the first  
  fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

· Check data quality. If much lower  
  than 100 percent, the problem may  
  be a bad data link connection, poor  
  quality or broken cables, missing  
  termination plug, or a defective   
  fixture disturbing the link. 

 
Bad data link connection 

· Inspect connections and cables.  
  Correct poor connections. Repair or  
  replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

· Insert termination plug in output jack  
  of the last fixture on the link. 

Incorrect addressing of the fixtures.  · Check address setting. 
 
 
One of the fixtures is defective and 
disturbs data transmission on the 
link. 

· Bypass one fixture at a time until  
  normal operation is regained: unplug  
  both connectors and connect them  
  directly together. 
· Have the defective fixture serviced  
  by a qualified technician. 

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

· Install a phase-reversing cable 
  between the fixtures or swap pin 2  
  and 3 in the fixture, that behaves  
  erratically. 

Shutter closes 
suddenly 

The shutter has lost its index 
position and the fixture is resetting 
the effect. 

· Contact a technician for servicing if  
  the problem persists. 

 
No light 

The power supply settings do not 
match local AC voltage and 
frequency. 

· Disconnect fixture. Check settings  
  and correct if necessary. 

LEDs damaged 

· Disconnect fixture and return to your  
  dealer. 

 
Lamp cuts out 
intermittently. 

 
Fixture is too hot. 

· Allow fixture to cool. 
· Clean fan. 
· Make sure air vents at control panel  
  and front lens are not blocked. 
· Turn up the air conditioning. 

 

The power supply settings do not 
match local AC voltage and 
frequency. 

· Disconnect fixture. Check settings  
  and correct if necessary. 

Summary of Contents for Expression 5000

Page 1: ...Expression 5000 V2 ORDERCODE 41364 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...in Programs Multiple Expression 5000s Master Slave control Multiple Expression 5000s DMX control Control Panel Control Mode DMX addressing MENU OVERVIEW Main Menu Options 1 Intro Menu DMX Addressing...

Page 4: ...00 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inclu...

Page 5: ...east 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used before cleaning or when replacing lamp Only handle the power cord by the plug Never pull out t...

Page 6: ...shock lamp explosion crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues...

Page 7: ...ty Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cabl...

Page 8: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 9: ...er selectable pan tilt ranges User selectable basic or advanced operating modes Power Consumption 140W max at full output Movement resolution selectable 8 16 bit Control On Board LCD display for Auto...

Page 10: ...ole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Oper...

Page 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Expressions on a DMX data link 30 fixtures Data Cabling To li...

Page 12: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Expression 5000 The pins 1 Earth 2 Signal 3 Signal 3 Lin...

Page 13: ...al cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords into...

Page 14: ...of the second Expression 5000 should be 1 12 13 013 the DMX address of the third Expression 5000 should be 13 12 25 025 etc Please be sure that you don t have any overlapping channels in order to cont...

Page 15: ...13 Menu Overview Once you have entered a step you will see menu 5 2 5 12...

Page 16: ...14...

Page 17: ...ress the MODE button to scroll through 8 options of the menu To see menu 7 and 8 You have to enter password UP DOWN UP DOWN in menu EXTRA When you use the menu button the 2 hidden menus will now appea...

Page 18: ...own buttons to go to the Fans menu 3 Press enter to open this menu Use the Up Down buttons to set the desired fan speed DMX Active With this menu you able to control the device by DMX 1 Press Menu unt...

Page 19: ...nu 3 Press enter to open this menu Scroll through the menu until the display shows TEST 4 When you press ENTER the display will blink once and the device will start an internal test Channels Advanced...

Page 20: ...ter button to store your setting 3 Range 1 Press Menu until the display shows Range 2 Press Enter and use the Up Down buttons to scroll through P Start P Finish T Start T Finish Use 3 Press enter to o...

Page 21: ...ps please set the last step as 0 For example when you have 3 steps the setting should be Step 1 Time 4 Use Yes Step 2 Time 5 Use Yes Step 3 Time 0 Use Yes 6 Extra Password 1 Press Menu until the displ...

Page 22: ...20 7 Calib...

Page 23: ...nt color temperatures 3 There are 11 pre programmed White colors and RGB TO WHITE They can be edited by mixing Red Green and Blue 8 Default 1 Press Menu until the display shows Default 2 Press Enter a...

Page 24: ...d 255 Channel 6 Red Dimmer must be open 0 255 Gradual adjustment Red from 0 100 Channel 7 Green Dimmer must be open 0 255 Gradual adjustment Green from 0 100 Channel 8 Blue Dimmer must be open 0 255 G...

Page 25: ...ted after 5 seconds 150 159 Auto 2 activated after 5 seconds 160 169 Test activated after 5 seconds 170 179 Custom activated after 5 seconds 180 189 Sound 1 190 199 Sound 2 200 219 Reset activated aft...

Page 26: ...0 255 Gradual adjustment Green from 0 100 Channel 5 Blue Dimmer must be open 0 255 Gradual adjustment Blue from 0 100 Channel 6 Macro Colors 0 10 No Function 11 30 Red 100 Green Up Blue 0 31 50 Red D...

Page 27: ...169 Test activated after 5 seconds 170 179 Custom activated after 5 seconds 180 189 Sound 1 190 199 Sound 2 200 219 Reset activated after 5 seconds 220 235 No Function 236 239 DIM 0 activated after 5...

Page 28: ...power Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens...

Page 29: ...ug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixt...

Page 30: ...anges User selectable basic or advanced operating modes Movement resolution selectable 8 16 bit Control On Board LCD display for Auto Custom Special Pan Tilt movement blackout Housing Flame retardant...

Page 31: ......

Reviews: