Problem
Probable cause(s)
Remedy
One or more
fixtures do not
function at all
No power to the fixture.
●
Check that power is switched on and
the battery is charged (green LED in
front
should light continuously).
Fixtures reset
correctly, but all
respond erratically
or not at all to the
controller.
The controller is not connected.
●
Connect controller.
3-pin XLR Out of the controller does
not match XLR Out of the
transmitter on the link (i.e. signal is
reversed).
●
Install a phase reversing cable between
the controller and the transmitter on the
link.
Fixtures reset
correctly, but some
respond erratically
or not at all to the
controller.
Poor data quality
●
Check data quality. If much lower than
100 percent, the problem may be a
bad data link connection, poor quality
or broken cables, missing termination
plug, or a defective fixture disturbing
the link.
Bad data link connection
●
Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables.
Incorrect addressing of the fixtures.
●
Check address setting.
One of the fixtures is defective and
disturbs data transmission on the
link.
●
Bypass one fixture at a time until normal
operation is regained: unplug both
connectors and connect them directly
together.
●
Have the defective fixture serviced by a
qualified technician.
No light
Fixture is too hot.
●
Allow fixture to cool.
●
Make sure air vents at control panel
and front lens are not blocked.
●
Turn up the air conditioning .
LEDS damaged
●
Disconnect fixture and return to your
dealer.
Summary of Contents for EVENTSPOT 60 Q7
Page 14: ...13 Ordercode 42727 Eventspot 60 Q7 Menu overview...
Page 32: ...31 Ordercode 42727 Eventspot 60 Q7 Dimensions...
Page 33: ...32 Ordercode 42727 Eventspot 60 Q7 Notes...
Page 34: ...33 Ordercode 42727 Eventspot 60 Q7...
Page 35: ...34 Ordercode 42727 Eventspot 60 Q7...
Page 36: ...2016 Showtec...