background image

 

Ordercode: 40296 

Data Flash Strobe  

Control Panel 

 

 

A)  LCD display 

B)  MODE button 

C)  SETUP button 

D)  UP button 

E)   DOWN button 

 

 

Fig. 05 

 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  

The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 

the controller will display the saved DMX address, next time.) 

 

DMX Addressing 

The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first 

channel with which the Data Flash Strobe will respond to the controller. 

Please note, when you use the controller, the unit has 12 channels. 

When using multiple Data Flash Strobes, make sure you set the DMX addresses right. 

Therefore, the DMX address of the first Data Flash Strobe should be 1(001); the DMX address of the 

second Data Flash Strobe should be 1+12=13 (013); the DMX address of the third Data Flash Strobe 

should be 13+12=25 (025), etc. Please, be sure that you do not have any overlapping channels in order 

to control each Data Flash Strobe correctly. If two or more Data Flash Strobes are addressed similarly, 

they will work similarly. 

 

Controlling: 

After having addressed all Data Flash Strobe

 

fixtures, you may now start operating these via your lighting 

controller. 

Note: After switching on, the Data Flash Strobe

 

will automatically detect whether DMX 512 data is 

received or not. If there is no data received at the DMX-input, the “LED “ on the control panel will not 

flash. 

If not, the problem may be: 

 

The XLR cable from the controller is not connected with the input of the Data Flash Strobe. 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 

swapped in the input connector. 

 

Note: It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link.  

 

 

Display Off after 60 seconds

 

 

It is possible to set a time for turning off the display. When no button is pressed for 10, 20, 30 or 60 seconds, 

the display will turn off. To light up the display, you have to press the MODE, SETUP, UP or DOWN buttons. 

Once you have pressed the button, the display will light up. 

 

 

 

  

 

 

12 

   

 

Summary of Contents for Data Flash Strobe

Page 1: ...Data Flash Strobe V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40296 MANUAL ENGLISH...

Page 2: ...trobe Sound controlled 9 Multiple Data Flash Strobes Master Slave control 9 Multiple Data Flash Strobes DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressin...

Page 3: ...includes Showtec Data Flash Strobe Pro power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of...

Page 4: ...is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep th...

Page 5: ...operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concer...

Page 6: ...h the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW CO...

Page 7: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 8: ...C 50 60Hz Power consumption 120W DMX channels 2 3 12 channels LCD display for easy setup Light source SMD LEDs Control modes Auto Built in Programs Sound controlled Master Slave DMX Control protocol D...

Page 9: ...d Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non...

Page 10: ...r supply socket 03 Turn on the music If the device is set to sound control then the Data Flash Strobe will react to the beat of the music Please see page 15 for more information about the sound contro...

Page 11: ...onnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric ma...

Page 12: ...ly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic...

Page 13: ...erlapping channels in order to control each Data Flash Strobe correctly If two or more Data Flash Strobes are addressed similarly they will work similarly Controlling After having addressed all Data F...

Page 14: ...Ordercode 40296 Data Flash Strobe Menu Overview 13...

Page 15: ...the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to toggle through the 25 built in programs 04 Once you have selected one of the programs press the SETUP butto...

Page 16: ...ble options are 5 Sound control Mode 01 Press the MODE button and then the UP DOWN buttons until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to set the so...

Page 17: ...ress the MODE button and then the UP DOWN buttons until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose between the 6 available options and 04 Press...

Page 18: ...on to open the menu and then press the UP DOWN buttons to choose Yes or No 11 Press the SETUP button again to confirm your choice If you have chosen Yes the factory settings will be restored 12 In the...

Page 19: ...l 2 Strobe Dimmer must be open 0 4 Closed 5 127 Linear strobe from low to high frequency 0 20Hz ALL LEDs 128 189 Random strobe from low to high frequency ALL LEDs 190 255 Random strobe RANDOM LED RING...

Page 20: ...m dark to brightest 0 100 Channel 7 Section 6 Dimmer must be open 0 255 Gradual adjustment section 6 from dark to brightest 0 100 Channel 8 Section 7 Dimmer must be open 0 255 Gradual adjustment secti...

Page 21: ...a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up re...

Page 22: ...missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not ter...

Page 23: ...effects Light source SMD LEDs Dimmer 0 100 Strobe 0 20Hz Housing Aluminum DMX control via standard DMX controller DMX 512 On Board LCD display for easy setup Control Auto Built in Programs Sound cont...