background image

 

  

 

 

   

 

Ordercode: 30277 

Compact Power Lightset  4 RGBW 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Regular operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be bigger than 1 
meter. 

 

The maximum ambient temperature ta = 40°C must never be exceeded. 

 

The relative humidity must not exceed  50 % w ith an ambient temperature of 40° C. 

 

If this device is operated in any other way than the one described  in this manual, the product may 
suffer damages and the warranty becomes  void. 

 

Any  other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others

 

Rigging 

Please follow t he European and nat ional guidelines concerning rigging, trussing and all 
ot her safety issues. 

 

Do not  attempt the installation yourself! 
Always let  the installation be carried out  by an aut horized dealer! 

 

Procedure

 

If the Compact Power Lightset 4 RGBW is lowered from the ceiling or high joists, professional 
trussing systems  have to be used. 

 

Use a clamp to mount the Compact Power Lightset 4 RGBW, with the mounting-bracket, to the 
trussing system. 

 

The Compact Power Lightset 4 RGBW must never be fixed swinging freely in the room.  

 

The installation must always be secured  with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the Compact Power Lightset 4 RGBW, always make sure, that 
the area below the installation place is blocked and staying in the area is forbidden.

 

 
The Compact Power Lightset 4 RGBW can be placed on a flat stage floor or mounted to any kind of truss 
by a clamp. 
 

Improper installation can cause serious injuries and/or damage of property!

 

 

Connection with the mains 

Connect the device to the mains with the power plug. 
Always check if the right color cable is connected  to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

PHASE

 

BLUE 

BLACK 

SILVER 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE  GROUND 

 

Make sure t hat the device is always connect ed 

properly 

t o t he earth! 

 

Improper inst allation can cause serious damage t o people and propert y! 

 

Summary of Contents for COMPACT POWER LIGHTSET 4 RGBW

Page 1: ...Compact Power Lightset 4 RGBW V1 Highlit e Int ernat ional B V Vest ast raat 2 6468 EX K erkrade t he Net herlands Ordercode 30277 MANUAL ENGLISH...

Page 2: ...s 8 Multiple Compact Power Lightsets 4 RGBW Master Slave control 8 Multiple Compact Power Lightsets 4 RGBW DMX512 Mode 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Add...

Page 3: ...ct Power Lightset 4 RGBW Stand T bar carrying bag and hard case incl IEC powercable 5 0m 2 safety eyes User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the domi...

Page 4: ...lose to flammable liquids or gases Always keep case closed while operating Always allow free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when dev...

Page 5: ...ightset 4 RGBW is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Compact Power Lightset 4 RGBW with the mounting bracket to the trussing...

Page 6: ...our phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perf...

Page 7: ...ate 7 8 Khz Control Mode DMX512 LED Source 5x 4 in 1 RGBW LEDs 4W per spot Dimmer 0 100 Strobe 0 20Hz Beam angle 25 Consumption Power 90 Watt 3 pin female XLR socket and 3 pin male XLR socket IEC Powe...

Page 8: ...ply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to w...

Page 9: ...0 5 meter on all sides for air circulation 02 When the Compact Power Lightset is not connected by a DMX cable it functions as a stand alone device 03 If device is set to or then the fixture will play...

Page 10: ...er devices 04 Link the units as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 05...

Page 11: ...ures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please u...

Page 12: ...should be 20 19 39 039 etc Please be sure that you do not have any overlapping channels in order to control each Compact Power Lightset 4 RGBW correctly If two or more Compact Power Lightsets 4 RGBW...

Page 13: ...12 Ordercode 30277 Compact Power Lightset 4 RGBW Menu overview...

Page 14: ...Setup button you can choose a different DMX Mode Select a DMX channel mode between The display will blink 2 Built in Programs With this menu you can choose a built in program 01 Press the Mode button...

Page 15: ...iew 2 info s about the device 01 Press the Mode button until the display shows 02 Press the Setup button to open the menu 03 Press the Up Down buttons to choose 04 Press the Setup button to open the m...

Page 16: ...sen Yes the factory settings will be restored The fixture will start up in the Auto Run mode 12 In the menu option you can set the device to Off or Hold 13 If you choose Off the fixture will blackout...

Page 17: ...device 01 Press the Mode button until the display shows 02 If the device has not been set to slave it is automatically classified as a master device All slave devices will follow the master movement...

Page 18: ...000 W200 28 34 Color 4 R255 G050 B000 W000 35 41 Color 5 R255 G150 B000 W000 42 48 Color 6 R255 G255 B000 W000 49 55 Color 7 R255 G255 B000 W075 56 62 Color 8 R000 G255 B000 W255 63 69 Color 9 R000 G2...

Page 19: ...75 Program 07 76 85 Program 08 86 95 Program 09 96 105 Program 10 106 115 Program 11 116 125 Program 12 126 135 Program 13 136 145 Program 14 146 155 Program 15 156 165 Program 16 166 175 Program 17...

Page 20: ...low to high frequency Channel 3 Red color intensity CH1 must be set between 001 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green color intensity CH1 must be set between 001 255 0 255 Gradua...

Page 21: ...olor intensity 0 255 Gradual adjustment Blue from 0 100 Channel 4 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 5 Red color intensity 0 255 Gradual adjustment Red from 0 100...

Page 22: ...W050 77 83 Color 11 R000 G255 B000 W000 84 90 Color 12 R000 G255 B050 W000 91 97 Color 13 R000 G255 B150 W000 98 104 Color 14 R000 G255 B255 W000 105 111 Color 15 R000 G255 B255 W075 112 118 Color 16...

Page 23: ...m Speed CH5 must be set between 006 235 0 255 Gradual speed adjustment from slow to fast Channel 6 Sound Sensitivity CH5 must be set between 236 255 0 255 Gradual sound sensitivity from low sensitivit...

Page 24: ...tment Blue from 0 100 Channel 4 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 5 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 6 Green color intensity 0...

Page 25: ...ue from 0 100 Channel 12 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 13 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 14 Green color intensity 0 255 G...

Page 26: ...e intensity from low to high frequency Channel 4 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 5 Green color intensity 0 255 Gradual adjustment Green from 0 100 Channel 6 Blue co...

Page 27: ...en from 0 100 Channel 14 Blue color intensity 0 255 Gradual adjustment Blue from 0 100 Channel 15 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 16 Red color intensity 0 255 G...

Page 28: ...ke sure connections are thoroughly dry before linking equipment or supplying electric power Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to bur...

Page 29: ...rrectly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or b...

Page 30: ...e Signal output 3 pin XLR female Electro mechanical effects Light source 5x 4 in 1 RGBW LEDs 4W per spot Beam Angle 25 Dimmer 0 100 Strobe 0 20Hz Color Range RGBW Cooling Aluminum heat sink Display LC...

Page 31: ...30 Ordercode 30277 Compact Power Lightset 4 RGBW Dimensions T bar 4 parcans Stand Weight stand 3 7 kg...

Page 32: ...2016 Showtec...