Maintenance 

The operator has to make sure that safety-relating  and machine-technical  installations are to be 
inspected by an expert after every year  in the course of an acceptance  test.  
The operator has to make sure that safety-relating  and machine-technical  installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered  during the inspection:  
01)

 

All screws used for installing the device or parts of the device have to be tightly connected  and must 
not be corroded. 

02)

 

There  may not be any deformations on housings, fixations and installation spots.  

03)

 

Mechanically  moving parts like axles, eyes  and others may not show any traces of wearing.  

04)

 

The electric power supply cables must not show any damages or material fatigue.  

 
The Showtec Compact Power Lightset 4 RGBW  requires almost no maintenance. However, you should 
keep the unit clean. Otherwise, the fixture’s light-output will be significantly reduced.  Disconnect the 
mains power supply and then wipe the cover with a damp cloth. Wipe the front glass panel clean with 
glass cleaner and a soft cloth. Do not use alcohol or solvents. The front glass panel will require weekly 
cleaning, as smoke-fluid tends to build up residues, reducing the light-output very quickly. Do not 
immerse in liquid. 
Keep connections clean. Disconnect electric  power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 
 

Replacing a Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause  a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below :

 

01)

 

Unplug the unit from electric power source

02)

 

Insert a flat-head screwdriver into a slot in the fuse cover. 

Gently  pry up the fuse cover.  

the fuse will come out.

 

03)

 

Remove the used fuse. If brown or unclear, it is burned out

04)

 

Insert the replacement  fuse into the holder where the old fuse was. Reinsert t he fuse cover. Be sure to 

use a fuse of the same type and specification.  See the product specification label for details. 

 

Troubleshooting 

 

No Light 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs,  follow the steps below in sequence  until a solution is found. Once the unit operates 
properly, do not carry  out the following steps. 
If the light effect does not operate properly, refer servicing to a technician.  
Response: Suspect  four potential problem areas as the power supply, the LEDs, the fuse. 
01)

 

Power supply. Check that the unit is plugged into an appropriate power supply.  

02)

 

The LEDs. Return the 

Compact Power Lightset 4 RGBW 

to your Showtec dealer. 

03)

 

The fuse. Replace the fuse. See  page 27 for replacing the fuse. 

04)

 

If all of the above appears to be  in order, switch the unit on again. 

05)

 

If you are unable to determine the cause  of the problem, do not open the 

Compact Power Lightset 

4 RGBW

, as this may damage the unit and the warranty will become void. 

06)

 

Return the device  to your Showtec dealer. 

 

 

Summary of Contents for COMPACT POWER LIGHTSET 4 RGBW

Page 1: ...Compact Power Lightset 4 RGBW V1 Highlit e Int ernat ional B V Vest ast raat 2 6468 EX K erkrade t he Net herlands Ordercode 30277 MANUAL ENGLISH...

Page 2: ...s 8 Multiple Compact Power Lightsets 4 RGBW Master Slave control 8 Multiple Compact Power Lightsets 4 RGBW DMX512 Mode 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Add...

Page 3: ...ct Power Lightset 4 RGBW Stand T bar carrying bag and hard case incl IEC powercable 5 0m 2 safety eyes User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the domi...

Page 4: ...lose to flammable liquids or gases Always keep case closed while operating Always allow free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when dev...

Page 5: ...ightset 4 RGBW is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Compact Power Lightset 4 RGBW with the mounting bracket to the trussing...

Page 6: ...our phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perf...

Page 7: ...ate 7 8 Khz Control Mode DMX512 LED Source 5x 4 in 1 RGBW LEDs 4W per spot Dimmer 0 100 Strobe 0 20Hz Beam angle 25 Consumption Power 90 Watt 3 pin female XLR socket and 3 pin male XLR socket IEC Powe...

Page 8: ...ply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to w...

Page 9: ...0 5 meter on all sides for air circulation 02 When the Compact Power Lightset is not connected by a DMX cable it functions as a stand alone device 03 If device is set to or then the fixture will play...

Page 10: ...er devices 04 Link the units as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 05...

Page 11: ...ures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please u...

Page 12: ...should be 20 19 39 039 etc Please be sure that you do not have any overlapping channels in order to control each Compact Power Lightset 4 RGBW correctly If two or more Compact Power Lightsets 4 RGBW...

Page 13: ...12 Ordercode 30277 Compact Power Lightset 4 RGBW Menu overview...

Page 14: ...Setup button you can choose a different DMX Mode Select a DMX channel mode between The display will blink 2 Built in Programs With this menu you can choose a built in program 01 Press the Mode button...

Page 15: ...iew 2 info s about the device 01 Press the Mode button until the display shows 02 Press the Setup button to open the menu 03 Press the Up Down buttons to choose 04 Press the Setup button to open the m...

Page 16: ...sen Yes the factory settings will be restored The fixture will start up in the Auto Run mode 12 In the menu option you can set the device to Off or Hold 13 If you choose Off the fixture will blackout...

Page 17: ...device 01 Press the Mode button until the display shows 02 If the device has not been set to slave it is automatically classified as a master device All slave devices will follow the master movement...

Page 18: ...000 W200 28 34 Color 4 R255 G050 B000 W000 35 41 Color 5 R255 G150 B000 W000 42 48 Color 6 R255 G255 B000 W000 49 55 Color 7 R255 G255 B000 W075 56 62 Color 8 R000 G255 B000 W255 63 69 Color 9 R000 G2...

Page 19: ...75 Program 07 76 85 Program 08 86 95 Program 09 96 105 Program 10 106 115 Program 11 116 125 Program 12 126 135 Program 13 136 145 Program 14 146 155 Program 15 156 165 Program 16 166 175 Program 17...

Page 20: ...low to high frequency Channel 3 Red color intensity CH1 must be set between 001 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green color intensity CH1 must be set between 001 255 0 255 Gradua...

Page 21: ...olor intensity 0 255 Gradual adjustment Blue from 0 100 Channel 4 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 5 Red color intensity 0 255 Gradual adjustment Red from 0 100...

Page 22: ...W050 77 83 Color 11 R000 G255 B000 W000 84 90 Color 12 R000 G255 B050 W000 91 97 Color 13 R000 G255 B150 W000 98 104 Color 14 R000 G255 B255 W000 105 111 Color 15 R000 G255 B255 W075 112 118 Color 16...

Page 23: ...m Speed CH5 must be set between 006 235 0 255 Gradual speed adjustment from slow to fast Channel 6 Sound Sensitivity CH5 must be set between 236 255 0 255 Gradual sound sensitivity from low sensitivit...

Page 24: ...tment Blue from 0 100 Channel 4 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 5 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 6 Green color intensity 0...

Page 25: ...ue from 0 100 Channel 12 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 13 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 14 Green color intensity 0 255 G...

Page 26: ...e intensity from low to high frequency Channel 4 Red color intensity 0 255 Gradual adjustment Red from 0 100 Channel 5 Green color intensity 0 255 Gradual adjustment Green from 0 100 Channel 6 Blue co...

Page 27: ...en from 0 100 Channel 14 Blue color intensity 0 255 Gradual adjustment Blue from 0 100 Channel 15 White color intensity 0 255 Gradual adjustment White from 0 100 Channel 16 Red color intensity 0 255 G...

Page 28: ...ke sure connections are thoroughly dry before linking equipment or supplying electric power Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to bur...

Page 29: ...rrectly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or b...

Page 30: ...e Signal output 3 pin XLR female Electro mechanical effects Light source 5x 4 in 1 RGBW LEDs 4W per spot Beam Angle 25 Dimmer 0 100 Strobe 0 20Hz Color Range RGBW Cooling Aluminum heat sink Display LC...

Page 31: ...30 Ordercode 30277 Compact Power Lightset 4 RGBW Dimensions T bar 4 parcans Stand Weight stand 3 7 kg...

Page 32: ...2016 Showtec...

Reviews: