Maintenance 

The Showtec Club Par Dizzy requires almost no maintenance. However, you should keep the unit clean. 
Otherwise, the fixture’s light-output will be significantly reduced.  
Disconnect the mains power supply and then wipe the cover with a damp cloth. Wipe the front glass 
panel clean with glass cleaner and a soft cloth. Do not use alcohol or solvents. The front glass panel will 
require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-output very quickly. 
Do not immerse in liquid.  
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 
 
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test.  
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection:  
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and must 
not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 

Replacing the Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below. 
01)

 

Unplug the unit from electric power source. 

02)

 

Insert a screwdriver into the slot in the fuse cover. Gently pry up the fuse cover. The fuse will come 
out. 

03)

 

Remove the used fuse. If brown or unclear, it is burned out. 

04)

 

Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to 
use a fuse of the same type and specification. See the product specification label for details. 

 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 
 

No Light 

If the light effect does not operate properly, refer servicing to a technician. 
Response: Suspect three potential problem areas as: the power supply, the lamp, the fuse. 
01)

 

Power supply. Check if the unit is plugged into an appropriate power supply. 

02)

 

The LEDs. Return the Club Par Dizzy to your Showtec dealer. 

03)

 

The fuse. Replace the fuse. See page 21 for replacing the fuse. 

04)

 

If all of the above appears to be O.K., plug the unit in again.  

05)

 

If you are unable to determine the cause of the problem, do not open the Club Par Dizzy, as this may 
damage the unit and the warranty will become void. 

06)

 

Return the device to your Showtec dealer. 

 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 
01)

 

Check the DMX setting. Make sure that DMX addresses are correct. 

02)

 

Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. 
Try your DMX control again. 

03)

 

Determine whether the controller or light effect is at fault. Does the controller operate properly with 
other DMX products? If not, take the controller in for repair. If so, take the DMX cable and the light 
effect to a qualified technician. 

 

Summary of Contents for Club Par Dizzy 3/8

Page 1: ...Club Par Dizzy 3 8 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42653 MANUAL ENGLISH...

Page 2: ...de 10 One Club Par Dizzy Sound controlled 10 Multiple Club Par Dizzy s Master Slave Mode 10 Multiple Club Par Dizzy s DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13...

Page 3: ...ating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving the lifes...

Page 4: ...operating Always allow a free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord...

Page 5: ...safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let t...

Page 6: ...Connection with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROW...

Page 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 8: ...d Power input 100 240V 50 60Hz Power linking Up to 16 Units Power consumption 45W LED Source 3 x 8W 4 in 1 RGB UV LEDs 27 x 0 5W Cool White SMD LEDs 18 x 0 5W RGB SMD LEDs Output 847 lux 2m Control mo...

Page 9: ...8 Ordercode 42653 Club Par Dizzy 3 8 Overview Fig 01 01 18 x 0 5W RGB SMD LEDs 02 3 x 8W 4 in 1 RGB UV LEDs 03 IR Sensor 04 27 x 0 5W Cool White SMD LEDs...

Page 10: ...Club Par Dizzy Check if all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains p...

Page 11: ...oper electric power supply socket 04 When the Club Par Dizzy is not connected with a DMX cable it functions as a stand alone device 05 Please see page 15 for more information about the Sound controlle...

Page 12: ...he Club Par Dizzy s and other devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link th...

Page 13: ...om a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic inter...

Page 14: ...9 19 019 etc Please make sure that you do not have any overlapping channels in order to control each Club Par Dizzy correctly If two or more Club Par Dizzy s are addressed similarly they will work si...

Page 15: ...14 Ordercode 42653 Club Par Dizzy 3 8 Menu Overview...

Page 16: ...oose your preferred built in show 06 Press the UP and DOWN buttons to adjust the speed of your preferred show The adjustment range is between from slow to fast 07 Press the ENTER button to set the spe...

Page 17: ...the settings 4 DMX 512 Mode 01 Press the MENU button until the display shows 02 Press the ENTER button to enter the menu 03 Press the UP and DOWN buttons to choose one of the available DMX channel mo...

Page 18: ...ignored by the fixture 10 While the display shows press the ENTER button to proceed to the Blackout DMX Fail Mode 11 Press the UP and DOWN buttons to choose between If the device has been set to and t...

Page 19: ...activate the Wash LEDs mode programs AP1 AP8 SP1 SP6 Beam LEDs auto mode Repeatedly press the button to activate deactivate the Beam LEDs mode programs Ab1 Ab10 Sb1 Sb10 Laser auto mode Repeatedly pre...

Page 20: ...Master Dimmer 0 255 Gradual adjustment from dark to brightest 0 100 9 channels Channel 1 Red You can only use 3 colors at a time 0 255 Gradual adjustment Red from 0 100 Channel 2 Green You can only us...

Page 21: ...hannel 8 White SMD LEDS outer ring 0 5 Off 6 30 Auto Program 1 Sound Program 1 31 55 Auto Program 2 Sound Program 2 56 80 Auto Program 3 Sound Program 3 81 105 Auto Program 4 Sound Program 4 106 130 A...

Page 22: ...ever If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a screwdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come o...

Page 23: ...ctions and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the lin...

Page 24: ...Blue UV Color functions Rainbow effect 6 Section RGB Patterns 10 Section Strobe Ring Light source 3 x 8W 4 in 1 RGB UV LEDs 27 x 0 5W Cool White SMD LEDs 18 x 0 5W RGB SMD LEDs Power linking Up to 16...

Page 25: ...24 Ordercode 42653 Club Par Dizzy 3 8 Dimensions...

Page 26: ...25 Ordercode 42653 Club Par Dizzy 3 8 Notes...

Page 27: ...26 Ordercode 42653 Club Par Dizzy 3 8...

Page 28: ...2019 Showtec...

Reviews: