Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place.

 

 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
 

Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 
 
 
 
 
 
 

      

Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

 

Summary of Contents for Cameleon Flood 7 RGB

Page 1: ...Cameleon Flood 7 RGB ORDERCODE 42689...

Page 2: ...sign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant sh...

Page 3: ...9 One Cameleon Flood Manual color control 9 One Cameleon Flood NO Sound control 9 Multiple Cameleon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabl...

Page 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Page 5: ...the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obvious...

Page 6: ...Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Flood 7 is lowered from the ceiling or high joists professional trussing systems have to be used Use a clam...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...erconnector DMX Connection Dedicated IP65 connector Lens Plate Tempered Glass Control DMX Auto Program Master slave IR remote Dimmer 0 100 Strobe 0 20Hz Beam Angle 40 degrees Housing Die Cast Aluminiu...

Page 9: ...ni DMX In 4 3 pin mini DMX Out 5 Power Out 6 Power IN Please make sure to obtain the XLR 3 pin to mini 3 pin cable 42708 to connect the device to DMX Please make sure to also obtain the remote control...

Page 10: ...extension cable 3m 42706 Power connection cable 3m 42707 DMX Extension cable 3m 42708 Special XLR to small 3 pin cable 3m 42709 Endcap when using the Cameleon outdoors make sure the last device in a c...

Page 11: ...functions as a stand alone device Please see page 14 for more information about the Auto run visual effects One Cameleon Flood Built in Programs 1 Fasten the effect light onto firm trussing Leave at...

Page 12: ...hown in Fig 3 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units You can use the same function...

Page 13: ...MX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into proper electric power suppl...

Page 14: ...lities and connector made by Neutrik Ordercode FL71150 1 5m FL713 3m FL716 6m FL7110 10m DMX Control Mode The fixtures are individually addressed on a data link and connected to the controller The fix...

Page 15: ...ss this button to activate the Built in program Mode The LEDs will blink yellow once indicating you re in built in program mode Then the LEDs will dim briefly and then indicate its current built in pr...

Page 16: ...er one value one digit is 6 seconds 6 Static Color Mode R 2 G 3 B 4 Press one of these buttons to activate manual color setting in combination with one of the numeric buttons 0 9 to select a certain p...

Page 17: ...spots 3 Mechanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue Troubleshooting No Ligh...

Page 18: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Page 19: ...dicated IP65 Powerconnector DMX Connection Dedicated IP65 connector Lens Plate Tempered Glass Dimmer 0 100 Strobe 0 20Hz Beam Angle 40 degrees Housing Die Cast Aluminium Black Powder Coat Finish Cooli...