SHOWTEC Cameleon Flood 7 RGB Manual Download Page 4

 

Warning 

 
 
 

 

 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 
 

Your shipment includes: 

• Cameleon Flood 7 RGB with special 3-pin to IEC powercable 1,35m 
• User manual

 

 

 

 

LED Expected Lifespan 

LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the acceleration 
of this decline. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal or singular 
optimum conditions. For this reason when all color LEDs are used at their fullest intensity, life of the LEDs is 
significantly reduced. It is estimated that a viable lifespan of 40,000 to 50,000 hours will be achieved 
under normal operational conditions. If improving on this lifespan expectancy is of a higher priority, place 
care in providing for lower operational temperatures. This may include climatic-environmental and the 
reduction of overall projection intensity. 

 

 
 
 
 
 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP! 

 

Safety Instructions 

Every person involved with the installation, operation and maintenance of this device has to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 
 
 
 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP!

 

 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

CAUTION! 

Keep this device away from rain and moisture! 

Unplug mains lead before opening the housing! 

Summary of Contents for Cameleon Flood 7 RGB

Page 1: ...Cameleon Flood 7 RGB ORDERCODE 42689...

Page 2: ...sign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant sh...

Page 3: ...9 One Cameleon Flood Manual color control 9 One Cameleon Flood NO Sound control 9 Multiple Cameleon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabl...

Page 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Page 5: ...the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obvious...

Page 6: ...Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Flood 7 is lowered from the ceiling or high joists professional trussing systems have to be used Use a clam...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...erconnector DMX Connection Dedicated IP65 connector Lens Plate Tempered Glass Control DMX Auto Program Master slave IR remote Dimmer 0 100 Strobe 0 20Hz Beam Angle 40 degrees Housing Die Cast Aluminiu...

Page 9: ...ni DMX In 4 3 pin mini DMX Out 5 Power Out 6 Power IN Please make sure to obtain the XLR 3 pin to mini 3 pin cable 42708 to connect the device to DMX Please make sure to also obtain the remote control...

Page 10: ...extension cable 3m 42706 Power connection cable 3m 42707 DMX Extension cable 3m 42708 Special XLR to small 3 pin cable 3m 42709 Endcap when using the Cameleon outdoors make sure the last device in a c...

Page 11: ...functions as a stand alone device Please see page 14 for more information about the Auto run visual effects One Cameleon Flood Built in Programs 1 Fasten the effect light onto firm trussing Leave at...

Page 12: ...hown in Fig 3 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units You can use the same function...

Page 13: ...MX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into proper electric power suppl...

Page 14: ...lities and connector made by Neutrik Ordercode FL71150 1 5m FL713 3m FL716 6m FL7110 10m DMX Control Mode The fixtures are individually addressed on a data link and connected to the controller The fix...

Page 15: ...ss this button to activate the Built in program Mode The LEDs will blink yellow once indicating you re in built in program mode Then the LEDs will dim briefly and then indicate its current built in pr...

Page 16: ...er one value one digit is 6 seconds 6 Static Color Mode R 2 G 3 B 4 Press one of these buttons to activate manual color setting in combination with one of the numeric buttons 0 9 to select a certain p...

Page 17: ...spots 3 Mechanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue Troubleshooting No Ligh...

Page 18: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Page 19: ...dicated IP65 Powerconnector DMX Connection Dedicated IP65 connector Lens Plate Tempered Glass Dimmer 0 100 Strobe 0 20Hz Beam Angle 40 degrees Housing Die Cast Aluminium Black Powder Coat Finish Cooli...

Page 20: ......

Reviews: