SHOWTEC 40312 Manual Download Page 6

 

  

 

 

   

 

Ordercode: 40312 

LED Aircone DMX 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 

customer’s responsibility. Highlite reser

ves the right to use its own discretion to repair or replace 

product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name. 

02)

 

Your address. 

03)

 

Your phone number. 

04)

 

A brief description of the symptoms. 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 
 

 

Summary of Contents for 40312

Page 1: ...LED Aircone DMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40312 MANUAL ENGLISH ...

Page 2: ... Up and Operation 7 Control Modes 7 One LED Aircone Sound controlled 7 One LED Aircone AUTO Mix Color Control 8 One LED Aircone Manual Control 8 Multiple LED Aircones DMX Control 8 Fixture Linking 10 Data Cabling 10 DIP switch setting for DMX Mode 11 DMX Address Quick Reference Chart 12 DMX Channels 13 6 channels 13 Maintenance 14 Replacing the Fuse 14 Troubleshooting 15 No Light 15 No Response to...

Page 3: ...es than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions Every p...

Page 4: ...at the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the lens is obviously damaged it has to be replaced So that its functions are not impaired due to cracks or deep scratches If device is droppe...

Page 5: ...he installation be carried out by an authorized dealer Procedure If the LED Aircone is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the LED Aircone with the mounting bracket to the trussing system The LED Aircone must never be fixed swinging freely in the room The installation must always be secured with a safety attachment e g an appro...

Page 6: ... number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of ...

Page 7: ...ilt in Programs Manual Sound 3 pin DMX In and 3 pin DMX Out Dipswitches for all settings Compact strong metal housing Sound controlled via built in microphone 6 DMX Channels Fuse T1AL 250V Dimensions Ø475 x 165 mm DxH Weight 10 1 Kg Frontside Fig 01 01 LED module 02 Ground Earth Connection 03 Fan 04 Power cable 1m 05 Microphone 06 Protection cover for dispwitches 07 3 pin DMX Out cable 1 4m 08 3 p...

Page 8: ...ion mode Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply The device can be music controlled by its built in microphone To use the Dipswitches you first have to unscrew the protection cover Fig 02 Control Modes Th...

Page 9: ...ightness of the Blue LEDs Brightness grades Example RED 00 Dipswitch Setting 0 10 Dipswitch Setting 25 01 Dipswitch Setting 50 11 Dipswitch Setting 100 Multiple LED Aircones DMX Control 01 When all dipswitches are turned off the LED Aircone is in DMX Mode 02 Fasten the effect light onto firm trussing Use a 30 kg rated or stronger C clamp bolted onto the Showtec LED Aircone bracket or set the LED A...

Page 10: ... as described on page 7 8 Built in or Sound controlled This means on the master device you can set your desired operation Mode and all slave devices will react the same as the master device 06 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not...

Page 11: ...igital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of fixtures on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can car...

Page 12: ...Explanation Since each unit has 6 channels each address advances 6 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate address DMX Dip Switches ON for each unit Flip appropriate DMX dip switches on each unit Example 2 02 If you want to give a LED Aircone a DMX address 133 you first have to find the number 133 in the DMX Address Quic...

Page 13: ...12 Ordercode 40312 LED Aircone DMX DMX Address Quick Reference Chart ...

Page 14: ... when CH6 is set between 128 255 Channel 3 Blue CH6 must be set between 0 31 and CH4 between 0 7 0 OFF 1 255 Blue LED intensity control from 0 to 100 Channel 3 Fade Out Fade In or Fade In Fade Out ON OFF CH6 must be set between 32 127 0 7 OFF 8 255 ON Channel 3 No Function when CH6 is set between 128 255 Channel 4 Macro Preset Colors CH6 must be set between 0 31 0 7 OFF 8 255 Macro ON Channel 4 No...

Page 15: ...he operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation...

Page 16: ...placing the fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the LED Aircones as this may damage the unit and the warranty will become void 06 Return the device to your Showtec dealer No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction ...

Page 17: ... replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly to...

Page 18: ... signal connector IN cable 1 4m Signal output 3 pin DMX signal connector OUT cable 1 4m Electro mechanical effects Never change lamps again 183 LEDs 63 Red 57 Green 63 Blue Control Modes DMX 512 Built in Programs Manual Sound Compact strong metal housing Sound controlled via built in microphone Max ambient temperature ta 40 C Minimum distance Minimum distance from flammable surfaces 0 5m Minimum d...

Page 19: ...18 Ordercode 40312 LED Aircone DMX Dimensions ...

Page 20: ... 2015 Showtec ...