background image

 

 

 

 

  7

 

 

 

 

 

3

 

製品の名称と構造   

Name and Structure of Product 

3.1 

本体名称 

Name of main body

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.2 

標準付属品

Standard accessories 

Primary filter

                   

    Secondary filter

               

Active carbon cassette     

 
 
 
 

・1次フィルタ

Primary filter

 

粉塵やヒュームを収集・吸着します 

Collecting /Adsorbing the fine dust and fume 

・2次フィルタ

Secondary filter

 

ブロアを粉塵から守ります

Protecting the circuit

 

and the blower 

・活性炭カセット

Active carbon cassette 

 

臭いを吸着します

Absorbing the odor 

・排気

HEPA

フィルタ

Exhaust

 

HEPA filter 

排気をクリーンにします

Exhaust treatment 

 

 

1

次フィルタ

/

カセット型消臭フィルタ

 

Primary filter / Zeolite Cassette Filter 

 

シェイキングモータ

 

Shaking motor 

活性炭カセット

 

Active carbon cassette

 

排気フィルタ

 

Exhaust filter

 

Exhaust

 

HEPA filter

 

 

吸込み口 

Suction port

 

排気口 

Exhaust port

 

 

AT パネル(操作パネル) 
AT-Panel(operation panel) 

ヒューズ BOX 

Fuse Box 

 

リモートコネクタ 

Remote

 

connector

 

主電源スイッチ 

MAIN POWER switch

 

 

2次フィルタ

 

Secondary filter

 

排気フィルタカバー

 

Exhaust filter cover

 

正面扉 

Front

 

door

 

Summary of Contents for Fumeresa CBA-1000AT-HC-DSA-V1

Page 1: ...d this instruction manual thoroughly and handle this machine correctly so that you can use it safely for a long time and enjoy its full performance Original instructions Symbols used in this manual WA...

Page 2: ...plosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigarette oil liquid ch...

Page 3: ...ion before operation 12 4 5 Operation procedure 12 5 Remote Cable Sold Separately 13 5 1 Electrical circuit diagram 13 5 2 Remote Cable 13 5 3 Color and signal of each wire 13 5 4 Remote operation and...

Page 4: ...Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical parts to fail...

Page 5: ...ctrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacki...

Page 6: ...CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeolite from scatteri...

Page 7: ...ndary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active ca...

Page 8: ...s included 4 2 AT AT panel Operating the product with a different power supply may cause a failure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is r...

Page 9: ...t on the button It is impossible to shake off during operation When quite a lot of shaking is repeated the filter is deteriorated If the red light don t switch off please change the primary filter 1 I...

Page 10: ...ration stops changes within the range from 0 2 to 0 2 Because there is a change in the atmospheric pressure and the temperature And the pressure representation might temporarily change because it is i...

Page 11: ...ime of restart However if the main power switch shut down by the blackout when suction level is changed during the operation machine starts in suction level before the change RESET switch Press and ho...

Page 12: ...re is less than 5 0 k pa When it is over 5 0 kPa lower it under 5 0 kPa by adjusting the suction hose Using the suction hose which is too thin and is clogged may cause failure by the load too much Con...

Page 13: ...cannot be short circuited with other wires Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is impossible to control at this time 4 7 analog outpu...

Page 14: ...nd 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Impedance 4 7 Red Filter clogging output signal Tra...

Page 15: ...equired output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when you change the suct...

Page 16: ...peration shake off total up 1 hours After stopping the operation Auto moving for50sec Hand operation shake off After stopping the operation put on the manual shake off button for 60 sec It has moved w...

Page 17: ...wer plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 snap locks of the f...

Page 18: ...Stopper plate If the shaking arm stops in the center part of the filter Connect the power plug and turn on the main power Danger Do not touch secondary filter and stopper plate Put on the manual shak...

Page 19: ...100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust filter 2 Replace new...

Page 20: ...pplicable fuse CBA 1000AT HC DSA V1 100 110V 10A CBA 1000AT HC DSA V1 CE 220 240V 5A Inspection item Frequency Description Filter case Before operation Is the case closed completely Exhaust status Onc...

Page 21: ...erheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation...

Page 22: ...22 9 Indication of DANGER Labels 10 Electrical Circuit Diagram Device Name Plate Prohibition label Prohibition of disassembly Warning label High voltage Electric name Plate...

Page 23: ...suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 EN60204 1 2006 others 12 Consumable Par...

Page 24: ...ase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge 574 0052 1 25 http www showadenki co jp e mail sales showadenki co jp manufacturing...

Reviews: