保守・点検 

Maintenance and Inspection

 

6.1 

保守点検時の注意事項

Cautions on maintenance and inspection

 

 

6.2 

フィルタの交換時期について 

Filter replacement timing

 

フィルタ目詰ランプが点灯しましたら、シェイキングを行ってください。それでも目詰まりランプが消えない時には

 

1次フィルタを交換してください。また、1次フィルタを交換しても、目詰まりランプが消えないときには、2次フィルタ
を交換してください。

 

When the Filter saturation lamp continues to light even after shake-off, and if the filter replacement 
indicator lamp does not turn OFF even after replacement of the primary filter (filter bag), replace the 
secondary (main) filter. 
 

6.3 

1次フィルタのシェイキングについて

Dust shake-off work for primary filter

 

 

ランプ点灯時・・・自動シェイキング 

 

ランプ消灯時・・・手動シェイキング 

* 

Lamp lights (4.2 AT-panel 

shaking)   

  Auto operation 

* 

Lamp off 

→ 

Hand

 

operation 

 

自動シェイキング(※運転時間の積算が 1 時間以上のとき  ) 
運転停止後、自動的に約50 秒間シェイキングします 

Auto

 

operation

 

shake-off

(※

total up

 

1 hours

 

 

After stopping the operation

  Auto-moving( for50sec.) 

 

手動シェイキング 
運転停止後、手動手払いボタンを約60秒間押し続けてください. 
(ボタンを押している間、シェイキングします) 

Hand

 

operation

 

shake-off 

After stopping the operation,    put

 

on the 

”manual

 

shake-off button

 

for 60 sec. 

(It has moved while put on the button) 

 

運転時間とランプ点灯(自動シェイキング)について 

積算 1 時間以内・・・自動ではシェイキングしません 

Less than 1 hours( total up)

・・・

Not shake-off with auto operation 

 
 
 
 
 
 
 

 

点検時は必ず電源を切り、コンセントからプラグを抜いて、電路遮断を

 

行ってください。

 

Make sure to turn OFF the main power, and disconnect the power plug 
from the electrical outlet to cut off the electricity before starting 
inspection.

 

 

摩耗や破損したフィルタをそのまま使用すると、吸込んだ粉塵を大気に再飛散
させ、電気部品の損傷となります。

 

機械の故障、事故を未然に防ぎ、

 

末永くご使用頂けますよう、点検、手入れは必ず行ってください。

 

Using a worn or damaged filter will release sucked dust to the 
atmosphere, and damage electrical parts. 
Make sure to inspect and maintain, to prevent failures and accidents in 
the product and use the product for a long time.

 

Summary of Contents for Fumeresa CBA-1000AT-HC-DSA-V1

Page 1: ...d this instruction manual thoroughly and handle this machine correctly so that you can use it safely for a long time and enjoy its full performance Original instructions Symbols used in this manual WA...

Page 2: ...plosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigarette oil liquid ch...

Page 3: ...ion before operation 12 4 5 Operation procedure 12 5 Remote Cable Sold Separately 13 5 1 Electrical circuit diagram 13 5 2 Remote Cable 13 5 3 Color and signal of each wire 13 5 4 Remote operation and...

Page 4: ...Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical parts to fail...

Page 5: ...ctrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacki...

Page 6: ...CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeolite from scatteri...

Page 7: ...ndary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active ca...

Page 8: ...s included 4 2 AT AT panel Operating the product with a different power supply may cause a failure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is r...

Page 9: ...t on the button It is impossible to shake off during operation When quite a lot of shaking is repeated the filter is deteriorated If the red light don t switch off please change the primary filter 1 I...

Page 10: ...ration stops changes within the range from 0 2 to 0 2 Because there is a change in the atmospheric pressure and the temperature And the pressure representation might temporarily change because it is i...

Page 11: ...ime of restart However if the main power switch shut down by the blackout when suction level is changed during the operation machine starts in suction level before the change RESET switch Press and ho...

Page 12: ...re is less than 5 0 k pa When it is over 5 0 kPa lower it under 5 0 kPa by adjusting the suction hose Using the suction hose which is too thin and is clogged may cause failure by the load too much Con...

Page 13: ...cannot be short circuited with other wires Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is impossible to control at this time 4 7 analog outpu...

Page 14: ...nd 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Impedance 4 7 Red Filter clogging output signal Tra...

Page 15: ...equired output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when you change the suct...

Page 16: ...peration shake off total up 1 hours After stopping the operation Auto moving for50sec Hand operation shake off After stopping the operation put on the manual shake off button for 60 sec It has moved w...

Page 17: ...wer plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 snap locks of the f...

Page 18: ...Stopper plate If the shaking arm stops in the center part of the filter Connect the power plug and turn on the main power Danger Do not touch secondary filter and stopper plate Put on the manual shak...

Page 19: ...100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust filter 2 Replace new...

Page 20: ...pplicable fuse CBA 1000AT HC DSA V1 100 110V 10A CBA 1000AT HC DSA V1 CE 220 240V 5A Inspection item Frequency Description Filter case Before operation Is the case closed completely Exhaust status Onc...

Page 21: ...erheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation...

Page 22: ...22 9 Indication of DANGER Labels 10 Electrical Circuit Diagram Device Name Plate Prohibition label Prohibition of disassembly Warning label High voltage Electric name Plate...

Page 23: ...suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 EN60204 1 2006 others 12 Consumable Par...

Page 24: ...ase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge 574 0052 1 25 http www showadenki co jp e mail sales showadenki co jp manufacturing...

Reviews:

Related manuals for Fumeresa CBA-1000AT-HC-DSA-V1