別売リモートケーブルについて 

Remote Cable (Sold Separately)

 

5.1 

電気回路図 

Electrical circuit diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.2 

ケーブル 

Remote Cable 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.3 

各線の色と信号について

Color and signal of each wire 

 

 

⑦(黄)は、他の線と短絡させないで下さい。

AT

パネルが損傷し、故障の

原因となります。

 

Do not short-circuit the wire [7] (yellow) with other wires. 
Such short-circuit may damage the AT panel, and cause 
failure.

 

⑦(黄)は、他の線と短絡しないよう収縮チュ
ーブの中に入っています。 

The wire [7] (yellow) is put inside a shrinkable 
tube so that it cannot be short-circuited with 
other wires.

 

 

リモート運転 

Remote operation switch 

リモートモード移行 
(ON 時に遠隔操作可能、この時パネル操作は不可) 

Shifting to remote mode 
(Remote control is possible in the ON, and the panel 
is impossible to control at this time.)

 

 

 

②圧力アナログ信号      出力  ≧4.7kΩ    ※温度補正なし 

Pressure 

analog output

  : 

Output 

impedance 4.7kΩ 

Temperature correction is not provided.

 

参照例

Reference

 

example 

インダクター(リレー等)を付加する場合は出力端子
(端子番号 3・5・6)にノイズリミッター(約 33Ω+0.1

μF)を付けて下さい 
Attach a  noise limiter (Approximately 33Ω+0.1μ

F)  to the output terminals(Nos.1.2 and 3) 
When adding inductors(such as relays) 

インダクタ(リレー等を付加する場合はノイズリミッター

(約33Ω+0.1μF)又はダイオード

等を付けて下さい

LOAD

LOAD

1

2

3

5

6

8

7

LOAD

LOAD

LOAD

運転入力信号

遠隔操作切替信号

運転圧力信号

フィルタ目詰信号

運転信号

過負荷信号

サービス電源

GND

DC 1~5V

耐圧 DC 50V

100mmA以下

DC 12V

Summary of Contents for Fumeresa CBA-1000AT-HC-DSA-V1

Page 1: ...d this instruction manual thoroughly and handle this machine correctly so that you can use it safely for a long time and enjoy its full performance Original instructions Symbols used in this manual WA...

Page 2: ...plosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigarette oil liquid ch...

Page 3: ...ion before operation 12 4 5 Operation procedure 12 5 Remote Cable Sold Separately 13 5 1 Electrical circuit diagram 13 5 2 Remote Cable 13 5 3 Color and signal of each wire 13 5 4 Remote operation and...

Page 4: ...Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical parts to fail...

Page 5: ...ctrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacki...

Page 6: ...CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeolite from scatteri...

Page 7: ...ndary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active ca...

Page 8: ...s included 4 2 AT AT panel Operating the product with a different power supply may cause a failure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is r...

Page 9: ...t on the button It is impossible to shake off during operation When quite a lot of shaking is repeated the filter is deteriorated If the red light don t switch off please change the primary filter 1 I...

Page 10: ...ration stops changes within the range from 0 2 to 0 2 Because there is a change in the atmospheric pressure and the temperature And the pressure representation might temporarily change because it is i...

Page 11: ...ime of restart However if the main power switch shut down by the blackout when suction level is changed during the operation machine starts in suction level before the change RESET switch Press and ho...

Page 12: ...re is less than 5 0 k pa When it is over 5 0 kPa lower it under 5 0 kPa by adjusting the suction hose Using the suction hose which is too thin and is clogged may cause failure by the load too much Con...

Page 13: ...cannot be short circuited with other wires Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is impossible to control at this time 4 7 analog outpu...

Page 14: ...nd 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Impedance 4 7 Red Filter clogging output signal Tra...

Page 15: ...equired output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when you change the suct...

Page 16: ...peration shake off total up 1 hours After stopping the operation Auto moving for50sec Hand operation shake off After stopping the operation put on the manual shake off button for 60 sec It has moved w...

Page 17: ...wer plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 snap locks of the f...

Page 18: ...Stopper plate If the shaking arm stops in the center part of the filter Connect the power plug and turn on the main power Danger Do not touch secondary filter and stopper plate Put on the manual shak...

Page 19: ...100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust filter 2 Replace new...

Page 20: ...pplicable fuse CBA 1000AT HC DSA V1 100 110V 10A CBA 1000AT HC DSA V1 CE 220 240V 5A Inspection item Frequency Description Filter case Before operation Is the case closed completely Exhaust status Onc...

Page 21: ...erheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation...

Page 22: ...22 9 Indication of DANGER Labels 10 Electrical Circuit Diagram Device Name Plate Prohibition label Prohibition of disassembly Warning label High voltage Electric name Plate...

Page 23: ...suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 EN60204 1 2006 others 12 Consumable Par...

Page 24: ...ase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge 574 0052 1 25 http www showadenki co jp e mail sales showadenki co jp manufacturing...

Reviews: