Pulse setting
Machine operation can also be regulated by changing the pulse settings in the event that the filter cloth
differential pressure is high or too low.
Function Setting
limits
Standard
setting
Filter cloth differential pressure
Dropping Rising
Pulse pressure
0.55 MPa to 0.7 MPa
0.6 MPa
High
Low
Pulsejet duration
0.15 to 0.4 sec.
0.2 sec.
Long
Short
Pulsejet interval
7 to 120 sec.
30 sec.
Short
Long
Note: Stick to the above settings during machine operation although it may be possible to set values outside these settings.
When the pulse settings are changed toward a lower filter cloth pressure, compressed-air consumption will
increase. So, the amounts of change should be minimised.
To change the pulse pressure, lift up the handle on top of the FR unit and turn it.
The pulsejet duration (on) and the pulsejet interval (off) can be changed by operating
the pulsejet selectors (switches) on the pulse control panel in the control box.
There is a possibility of electric shock inside the control box. Before changing the setting, take measures to
prevent electric shock such as turning off the power or wearing rubber gloves.