background image

 

Maintenance

 

The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by a skilled person once a year. 
The following points have to be considered during the inspection: 

1.

 

All screws used for installing the device or parts of the device have to be tightly connected and must 
not be corroded. 

2.

 

There may not be any deformations on housings, fixations and installation spots. 

3.

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

4.

 

The electric power supply cables must not show any damages or material fatigue. 

 

The 

Showtec Easy Fade 36 

requires almost no maintenance. However, you should keep the unit clean.  

Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in 
liquid. Do not use alcohol or solvents. 
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 

 

 

Troubleshooting 

 

No Light 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 
If the Easy Fade 36 does not operate properly, refer servicing to a technician. 
Response: Suspect two potential problem areas: the power supply, the LEDs. 

1.

 

Power supply. Check that the unit is plugged into an appropriate power supply. 

2.

 

The LEDs. Return the Easy Fade 36 to your Showtec dealer. 

3.

 

A led effect does not respond to the Easy Fade 36: Check the DMX-address of the fixture and the 
controller. Make sure they match. Make sure the connections are correct. Check if blackout is off. 

4.

 

If all of the above appears to be O.K., plug the unit in again. 

5.

 

If nothing happens after 30 seconds, unplug the device. 

6.

 

If you are unable to determine the cause of the problem, do not open the Easy Fade 36, as this may 
damage the unit and the warranty will become void. 

7.

 

Return the device to your Showtec dealer. 

 
 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 

1.

 

Check the DMX setting. Make sure that DMX addresses are correct. 

2.

 

Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. 
Try your DMX control again. 

3.

 

Determine whether the controller or light effect is at fault. Does the controller operate properly with 
other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light 
effect to a qualified technician. 

 

  

 

Summary of Contents for Easy Fade 36

Page 1: ...Easy Fade 36 ORDERCODE 50711...

Page 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...2 Operating Determinations 3 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Top 6 Backside 7 Installation 7 Set Up and Operation 7 Fixture Linking 8 Data Cabling 8 Maintenance 9 T...

Page 4: ...instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the device To maintai...

Page 5: ...osed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reac...

Page 6: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 7: ...ls Can be used either as a double preset 18 channel desk or as a single preset 36 channel desk Equipped with two Master faders and a grand master The Easy Fade 36 has no programming facilities in orde...

Page 8: ...button 1 2 Preset button To switch between the 18CH Mode and 36CH Mode Preset 1 36CH Mode Master Fader A is CH1 CH18 Master Fader B is CH19 CH36 Preset 2 18 CH Mode Preset A B is controlled by Master...

Page 9: ...to 0 or off usually on a temporary basis DMX 512 is an industry standard digital communication protocol used in entertainment lighting equipment For more information read Sections DMX Primer and DMX C...

Page 10: ...r may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of light effects s on a DMX data link 30 fixtures Data Cabling...

Page 11: ...If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the Easy Fade 36 does not operate properly refe...

Page 12: ...6 channel desk Equipped with two Master faders and a grand master The Easy Fade 36 has no programming facilities in order to keep it simple to use for any user Power connector Adaptor included NO Scen...

Page 13: ......

Reviews: