Cleaning filter material.
7.1.2.
Clean filter material when the water flow at filter output is insufficient and counter-washing, previous paragraph, did not lead to
any improvement.
Proceed as follows:
1. Turn off the filter supply pump.
2. Open the tank ring (Fig. 2, # 10).
3. Lift the cover (Fig. 2, # 5a).
4. Remove the filter tank (Fig. 2, # 7b) and clean it with running water.
5. Remove the purification tank (Fig. 2, # 8a) and clean it with running water.
6. Reassemble the tanks.
7. Make sure the cover O-ring (Fig. 2, # 5b) is in its housing. Otherwise, lubricate it with the supplied silicon oil and replace it in
the groove in the tank (Fig. 2, # 9).
8. Position and close the tank ring.
9. Turn on the filter supply pump.
7.2. Scheduled maintenance.
UV-C lamp replacement (Fig. 2, Fig. 7 and Fig. 8).
7.2.1.
This consists in replacing the UV-C lamp
18
, at least once a year or earlier if necessary. Proceed as follows:
1. Unscrew the UV unit cover fastening screw UV (Fig. 2, # 1b e Fig. 8).
2. Unscrew the UV-C lamp from the socket (Fig. 7) on the board (Fig. 2, # 1a).
3. Remove the UV-C lamp from the box (Fig. 2, # 2), being careful not to touch it with your bare hands
19
.
4. Screw the UV-C lamp into the socket (Fig. 7) on the board (Fig. 2, # 1a)
5. Install the UV unit cover (Fig. 2, # 1a e Fig. 8).
6. Screw in the UV unit cover fastening screw UV (Fig. 2, # 1b e).
7. Connect the product to the power mains.
If installation is correct, a blue light will turn on using the check light (do not place the check light in direct sunlight).
7.3. Extraordinary maintenance.
Extraordinary product maintenance must be performed by a specialised technician.
This consists in replacing worn or damaged parts (supply cord, hose support, test tube, gaskets, etc.).
18
The UV-C lamp has a 6,500 hour working life equal to about 270 days of continuous operation.
19
Do not touch the UV-C lamp and test tube with your bare hands. Impurities, dirt and grease on hands could jeopardise
product performance.