-11-
W1772/W1773 37" Drum Sander
EL
EC
TR
IC
A
L
ELECTRICAL
DO.NOT.work.on.your.electrical.system.
if. you. are. unsure. about. electrical.
codes.and.wiring!.Seek.assistance.from.
a. qualified. electrician.. Ignoring. this.
warning.can.cause.electrocution,.fire,.
or.machine.damage.
W1772.Single-Phase.240V.
Operation
The Model
W1772 is wired for 240V single-phase opera-
tion.
This machine must be hardwired to a locking shutoff
switch (
Figure.2
) by a qualified electrician. Since hardwir-
ing involves a permanent installation with conduit runs,
this task can only be safely accomplished by a qualified
electrician. As always, observe all applicable electrical
codes when connecting this machine to power.
This machine must be grounded! Verify the ground before
connecting this machine to the power source.
The. machine. must. be. properly. set. up. before. it. is.
safe.to.operate..DO.NOT.connect.this.machine.to.the.
power.source.until.instructed.to.do.so.in.the."Power.
Connection".portion.of.this.manual.
W1772.Electrical.
Specifications
Voltage
Amp.Draw
Min..Circuit.Size
Connection
Cord
Extension.Cord
240V
47A
60
Hardwire
Conduit Setup
N/A (Hardwire Only)
Figure.2.
Locking shutoff switch.