![Shop fox W1708 Owner'S Manual Download Page 27](http://html1.mh-extra.com/html/shop-fox/w1708/w1708_owners-manual_1259184027.webp)
-25-
W1708 Owner's Manual (Mfg. 10/07+)
SE
RV
IC
E
Miter Gauge Calibration
At 90˚ the miter gauge should be perpendicular to the
face of the wheel when it is mounted in the table slot. If
not, follow this procedure.
To calibrate the miter gauge, do these steps:
1.
DISCONNECT MACHINE FROM POWER!
2.
Use a try square or machinist’s square with one edge
against the face of the miter gauge and the other
against the disc face, as shown in
Figure 16.
3.
Loosen the lock knob on the miter gauge and adjust
the face of the miter gauge so it is flush with the
edge of the square, tighten the gauge lock knob, and
verify the setting.
4.
Using a Phillips head screwdriver, loosen the degree
scale pointer, position the pointer on 90˚, then
retighten the screw.
5.
Recheck the miter scale accuracy with the square.
Figure
16
.
Squaring miter gauge to disc.