-7-
W1708 Owner's Manual (Mfg. 10/07+)
EL
EC
TR
IC
A
L
ELECTRICAL
110V Operation
The Model W1708 is wired for 110V operation. The power
supply circuit used for this machine MUST be grounded
and rated for the amperage given below. Never replace
a circuit breaker with one of higher amperage without
consulting a qualified electrician to ensure compliance
with wiring codes.
This machine must be grounded! The electrical cord
supplied with this machine comes with a grounding pin. If
your outlet does not accommodate a ground pin, have it
replaced by a qualified electrician.
If you are unsure about the wiring codes in your area
or you plan to connect your machine to a shared
circuit, you may create a fire or circuit overload
hazard—consult a qualified electrician to reduce this
risk.
Operating Voltage
Amp Draw
Min. Circuit Size
Plug/Recommended Plug
Extension Cord
110V Operation
10 Amps
15A
NEMA 5-15
14 Gauge
DO NOT work on your electrical system
if you are unsure about electrical
codes and wiring! Seek assistance from
a qualified electrician. Ignoring this
warning can cause electrocution, fire,
or machine damage.
Figure
1
.
5-15 plug and receptacle.
Electrical Specifications
We do not recommend using an extension cord; however,
if you have no alternative, use the following guidelines:
• Use a cord rated for Standard Service (S).
• Do not use an extension cord longer than 50 feet.
• Ensure that the cord has a ground wire and pin.
• Use the gauge size listed below as a minimum.
Extension Cords
The machine must be properly set up before it is
safe to operate. DO NOT connect this machine to the
power source until instructed to do so in the "Test
Run" portion of this manual.
This machine comes with a plug, similar to
Figure
1
, to connect the machine to power.
Power Connection
Device