background image

14

OPERATING HEATER

 

 

 

 

 

Shutting Off Heater

1.  Press in and turn control knob clockwise

 to the HI position.

2. 

to 

3.  Press in control knob and turn clockwise

 to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1.  Turn the control knob clockwise

to 

the HI position.

2.  Press in and turn control knob clockwise

 to the pilot position.

Figure 7 - Control Knob and Ignitor Button 

                   Location 

    CAUTION: Do not try to adjust 

heating levels by using the 

equip-

ment shutoff valve. 

TO TURN GAS OFF 

   TO APPLIANCE

Turn the control knob clockwise

 

the PILOT position.

 

 

continued

4.

 

Press in and turn control knob clockwise 

 the 

OFF

 position (s

ee 

Figure 7

).

to

5.  Wait 

five

 (5) minutes to clear out any gas. Then 

smell for gas, including near the 

oor. 

If you smell gas, STOP! Follow “B” in the safety 

information, column 1, page 14. If you don’t

smell gas, go to the next step.

6.

 

Press in and turn control knob counterclockwise 

  to  the 

PILOT

  position. Press in control knob 

 

Note:

 You may be running this heater for the first  

time after hooking up to gas supply. If so, the control

knob may need to be pressed in for 30 seconds or more. 

7.  With control knob pressed in, press and release the 

ignitor button. This will light pilot. The pilot is attached 

 

Note:

 If pilot does not light (no spark), contact a qual-

ified service

 person or gas supplier for repairs. Until re- 

with match,  see 

Manual Lighting Procedure

, page 15.

8.

 

Keep control knob pressed in for 30 seconds after lighting 

pilot. After 30 seconds, release control knob.  

•  If control knob does not pop out when released, 

 contact a quali

ed ser

v

ice person or gas supplier for re-

 

for 

five

 (5) seconds (see 

Figure 7

). 

This will allow air to bleed from the gas system.  

to the front burner. If needed, keep pressing ignitor but-  

ton until pilot lights.

pairs are made, light pilot with match. To light pilot 

 

  If  pilot  goes  out,  repeat  steps  4  through 8.

9.  Slightly push in and turn control knob counterclockwise 

 to the 

ON

 position.

10.  Wait one minute and switch selector switch to the 

ON 

position to light burners. 

11.

 

Set 

ame  adjustment  knob  to  any  le

v

el between 

HI

 and 

LO.

Note:

 pairs.

 

  WARNING:  Make  sure  the selector   

-

ly with selector switch in the ON position.

Note:

 The pilot 

flame

 on natural gas units will 

have

 a slight 

curve,

 but 

flame

 should be blue 

and have no yellow o

r orange color.

switch  is  in  the  OFF position when you  

are away from home for long periods of   

time. Heater may  come  on  automatical

Figure 8 - Pilot (Propane/LP)

Ignitor Electrode

Pilot Burner

Figure 9 - Pilot (Natural)

Ignitor 

Electrode

Pilot Burner

(located on LEFT

SIDE of unit)

Summary of Contents for GEORGIA REGAL

Page 1: ...LLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This app liance is not convertible for use with other gases Aftermarket Completion of sale not...

Page 2: ...replace screen is in place before funning this app liance Unless other provisions are made for comb ustion air the screens shall have an opening or openings for introduction of combustion air into the fireplace If this appliance is installed in a fireplace that has glass doors the doors must be left open when the appliance is in use WARNING This product can expose you to chemicals including lead a...

Page 3: ... system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages 17 through 20 11 Do not run appliance where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this appliance to cook food or burn paper or other objects 13 Never place any ob...

Page 4: ...s no matches batteries or other sources to light heater PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code and Ventilation All spaces in homes fall into one of the following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space Theinformationonpages4through6willhelpyouclassify your space and provide adequate ventilation WARNING This heater s...

Page 5: ...outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Figure 1 Ventilation Air from Inside Building Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 2 VentilationAir from Outdoors DETERMINING FRESH AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confin...

Page 6: ...may be operated does not meet the required volume for indoor combustion air combustion and ventilation air shall be provided by one of the methods described intheNationalFuelGasCode ANSIZ223 1 NFPA 54 the International Fuel Gas Code or applicable local codes CONTINUED VENTED OPERATION Area of Various Standard Round Flues Diameter ins Area sq ins 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq...

Page 7: ...inyl or cloth wall cover ingsoroperatingappliancewhereimpurities suchastobaccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing appliance in rooms without enough ventilation air may cause mildew to form CHECK GAS TYPE Use the correct gas type natural gas or pro...

Page 8: ...uce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If you do not reduce incoming gas pressure heater regulator damage could occur Install the external regulator with the vent pointing down as shown in Figure 4 Pointing the vent down protects it from freezing rain or sleet INSTALLATION CLEARANCES WARNING Maintaintheminimumclear ances Mantel Clearances for Install...

Page 9: ...at you install a sediment trap in supply line as shown in Figure 5 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into appliance gas controls If sediment trap is not installed or is instal...

Page 10: ...n gas valve located on or near gas meter of natural gas or by using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane supply to equipment shutoff valve for propane gas Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once CONTINUED 10 REMOTE CONTROL SET INSTALLATION AND OPERATION COMMUNICATI...

Page 11: ...ly function is to be decorative Simply spread the Crushed Shale on your fireplace floor around the bottom of your log set burner grate to give the appearance of burnt ash It can also be used to cover your gas supply Caution Never place the shale or any other object not provided with your gas log set and instructed for that purpose onto the burners of the unit Be creative in the placement You do no...

Page 12: ... midway back on grate Log 4 in notches at left Log 5 in notches at right Place log 1 at back Log 6 crossing Log 4 at the top left to Log 1 Center in fireplace Log 3 at front of grate Place Logs 7 and 8 on the Log 1 Log 4 Log 3 Log 2 Log 5 Log 6 Log 7 Log 8 1 2 3 4 5 6 7 8 ...

Page 13: ...NS WARNING If operate this heater with glass doors closed If you operateheaterwith doorsclosed heat buildup inside fireplace willcauseglasstoburst Make suretherearenoobstructions across openings of fireplace You must operate this heater with sure fireplace screen is closed before running heater NOTICE Duringinitialoperationof new heater burning logs will give off a paper burning smell Orange flame wi...

Page 14: ...ton This will light pilot The pilot is attached Note If pilot does not light no spark contact a qual ified service person or gas supplier for repairs Until re with match see Manual Lighting Procedure page 15 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact a qualified service person or gas...

Page 15: ... Replace or remove low batteries as soon as possible to prevent corrosion damage to remote control acces sory 15 HAND HELD TRANSMITTER OPERATION Move the side Slide Switch into the ON position tow ards the flat end of the unit Press and hold the control button see Figure 11 on the Hand Held Remote until burner turns on Press and hold the control button again until the burner turns off Figure 11 ON...

Page 16: ...nd let cool Remove blockage Blocked burner flame holes will create soot MAIN BURNER BURNER FLAME PATTERN Figure 15 shows the correct burner flame patern Figure 16 shows the incorrect burner flame patern turn Gas Log Set off see Turning OFF the Ap pliance page 15 see Cleaning and Maintenance this page see Troubleshooting page 22 CLEANING AND MAINTENANCE WARNING Turn off Gas Logs and let CAUTION keep...

Page 17: ... See Fig 18 See Fig 18 Figure 18 Pilot Inlet Air Hole 19 17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...Model Number GRVFE24 N L 1 2 3 4 9 10 11 11 L 14 7 O O 5 0 0 6 0 0 o 8 311 20 24 12 o 13 L 14 15 16 21 17 18 19 22 25 24 23 20 ...

Page 21: ...0 Decorative Rock RMH 120 EBTBR RMH 120 EBTBR Tray Bracket Right 1 1 Tray Bracket Left RMH 120 EBTBL RMH 120 EBTBL RMH 120 00260 RMH 120 00254 RMH 120 18318 RMH 120 08419 NG RMH 120 08421 P RMH 120 90434A SBNCJ00071A SH 111 RMH 120 00051 49738375 Orifice Holder EB Tee 375 Comp Tube 375 EB Elbow Piezo Igniter RMH 120 90945 RMH 120 90945 RMH 120 00546 RMH 120 CMPT RMH 120 CMPT RMH 120 1831805 RMH 12...

Page 22: ... low pilot will not stay lit heater will not produce the specified heat propane gas supply volume may be low You may feel your gas pressure is too low If so contact your local natural or propane gas supplier Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty TECHNICAL SERVICE You may have further questions about installation opera ti...

Page 23: ...NOTES 23 ...

Page 24: ...coloring of any kind use or installation contrary to specified instructions and applicable building codes including heating the product to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alteration misuse abuse hostile environments or improper installation repair...

Reviews: