OPERATING HEATER
Shutting Off Heater
1. Press in and turn control knob clockwise
to the HI position.
2.
to
3. Press in control knob and turn clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn the control knob clockwise
to
the HI position.
2. Press in and turn control knob clockwise
to the pilot position.
Figure 7 - Control Knob and Ignitor Button
Location
CAUTION: Do not try to adjust
heating levels by using the
equip-
ment shutoff valve.
TO TURN GAS OFF
TO APPLIANCE
Turn the control knob clockwise
the PILOT position.
continued
4.
Press in and turn control knob clockwise
the
OFF
position (s
ee
Figure 7
).
to
5. Wait
five
(5) minutes to clear out any gas. Then
smell for gas, including near the
fl
oor.
If you smell gas, STOP! Follow “B” in the safety
information, column 1, page 14. If you don’t
smell gas, go to the next step.
6.
Press in and turn control knob counterclockwise
to the
PILOT
position. Press in control knob
Note:
You may be running this heater for the first
time after hooking up to gas supply. If so, the control
knob may need to be pressed in for 30 seconds or more.
7. With control knob pressed in, press and release the
ignitor button. This will light pilot. The pilot is attached
Note:
If pilot does not light (no spark), contact a qual-
ified service
person or gas supplier for repairs. Until re-
with match, see
Manual Lighting Procedure
, page 15.
8.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released,
contact a quali
fi
ed ser
v
ice person or gas supplier for re-
for
five
(5) seconds (see
Figure 7
).
This will allow air to bleed from the gas system.
to the front burner. If needed, keep pressing ignitor but-
ton until pilot lights.
pairs are made, light pilot with match. To light pilot
If pilot goes out, repeat steps 4 through 8.
9. Slightly push in and turn control knob counterclockwise
to the
ON
position.
10. Wait one minute and switch selector switch to the
ON
position to light burners.
11.
Set
fl
ame adjustment knob to any le
v
el between
HI
and
LO.
Note:
pairs.
WARNING: Make sure the selector
-
ly with selector switch in the ON position.
Note:
The pilot
flame
on natural gas units will
have
a slight
curve,
but
flame
should be blue
and have no yellow o
r orange color.
switch is in the OFF position when you
are away from home for long periods of
time. Heater may come on automatical
Figure 8 - Pilot (Propane/LP)
Ignitor Electrode
Pilot Burner
Figure 9 - Pilot (Natural)
Ignitor
Electrode
Pilot Burner
(located on LEFT
SIDE of unit)