VAL6 KBE5S Trouble Shooting
Possible Cause
How to check
Result
Remedy
Reference
Phenomenon
4
.
Combustion
stops during
Misfire lamp
is lit.
Air leak
Check looseness of each
joint
If heater ignites by
tightening joints, air leak
is the problem
Fasten joints more
tightly
Insufficient
amount of
pumping fuel
because vacuum
forms in tank
Check if air intake of
fuel gauge is clogged
with dust
If air intake of fuel
gauge is clogged,
amount of fuel flow
becomes insufficient
because of vacuum
Clean air intake of
fuel gauge
Picture 10
Shortage of light
detected by flame
monitor
Take flame monitor out,
and then check clarity of
its lens
If lens of flame monitor
is dirty, it detects a little
light
Wipe lens of
flame monitor
with soft cloth
Remove burner, and
then check clarity of
draft tube and vane
If draft tube or whirl
vane is dirty, flame
monitor detects little
Clean draft tube
and whirl vane
Picture 7
Flame monitor
connector is loose
connection
Plug flame monitor
connector (CN 11)
again, and then turn on
If it works normally,
flame monitor connector
fails on contact
Plug connector
(CN 11) firmly
Failure of flame
monitor
Unplug flame monitor
connector (CN 11), and
then check transition of
resistance by changing
quantity of light into
flame monitor
If resistance doesn't
change, flame monitor
fails
Replace flame
monitor
Nozzle clogged
Replace nozzle
If it works normally,
nozzle was clogged
Replace nozzle
Filter clogged
Check clarity of filter
If filter is dirty, fuel
flow decreases because
of clogged filter
Clean or replace
filter