VAL6 KBE5S Trouble Shooting
Possible Cause
How to check
Result
Remedy
Reference
Phenomenon
6
.
Smoke
comes out.
Shortage of
combustion air
Check extent of
combustion air inlet
opening
If combustion air inlet is
too small, it burns in
short of oxygen
Extend
combustion air
inlet opening.
Normal scale: 3
Decrease of air
brought from fan
Check if fan is dusty
If fan is dusty, it is short
of air
Clean fan
Decrease
revolutions of the
fan
Measure voltage at
power source connector
If voltage at power
source is lower than
standard, combustion air
is decreased because of
low voltage
Check voltage
(Power source
voltage is
insufficient)
Standard: AC120V
Nozzle clogged
Replace nozzle
If it works normally,
nozzle was clogged
Replace nozzle
Using at high
altitude area (Low
oxygen
concentration)
Know the altitude
If using at higher than
the altitude of 3300ft,
heater burns imperfectly
because of lack of
oxygen
Extend
combustion air
inlet opening.
Normal scale: 3
Wrong nozzle
Check makers imprint of
the nozzle
Mark: 0.85USgal/h 60°
H
If makers imprint is
incorrect, the nozzle is
should not be used
Replace to a
correct nozzle
8
Summary of Contents for VAL6 KBE5S