Air Conditioner Service Manual
Protection display code list:
Protection type
LED CODE
DIGITAL LED CODE
higher or lower voltage
RUN-winking,TIMER-1 time/8s
P1
Over current
RUN- winking,TIMER-2 times /8s
P2
Discharge temperature
RUN- winking,TIMER-4 times /8s
P4
Over cooling in cooling mode
RUN-light,TIMER-5 times /8s
P5
Over heating in cooling mode
RUN- light,TIMER-6 times /8s
P6
Over heating in heating mode
RUN- light,TIMER-7 times /8s
P7
Outdoor temperature too high or low
RUN- light,TIMER-8 times /8s
P8
Drive protection(Overload)
RUN- winking,TIMER-9 times/8s
P9
Module self protection
RUN- winking,TIMER-10 times/8s
P0
z
Outdoor failure display
There is a LED on outdoor power board, when compressor is running; it is normally light;
when no feedback of signal to power board from compressor, it will wink by lighting 1s and
going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go
out 3s for a cycle to indicate failures. The failure list is the follow:
Wink time
Failure
1
IPM protection
2
higher or lower voltage
3
Over current
4
Discharge temperature too high
5
Outdoor coil temperature too high
6
Drive abnormity
7
Communication abnormity with indoor unit
8
Compressor over heat
(
switch on top of compressor
)
9
Outdoor air temperature sensor failure
10
Outdoor coil temperature sensor failure
11
Outdoor discharge pipe temperature sensor failure
12
Voltage sensor failure
13
Current sensor failure
14 IPM
abnormity
15
Outdoor communication abnormity
16
DC fan motor no feedback
17 defrosting
57
Summary of Contents for SSH-I074BE
Page 18: ...Louver Pipes and Power Air Conditioner Service Manual 18 ...
Page 19: ...Air Conditioner Service Manmual 19 ...
Page 22: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL SSH I184BE INDOOR UNIT OUTDOOR UNIT 22 ...
Page 23: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL SSH I244BE INDOOR UNIT OUTDOOR UNIT 23 ...
Page 26: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL INDOOR UNIT OUTDOOR UNIT 26 ...