DECLARATION OF CONFORMITY

EU EMC Directive 2014/30/EU
The Low Voltage Directive 2006/95/EG
Medical Devices Directive 93/42/EEC

Manufacturer

Shire Controls Ltd
Studio 3 Channocks Farm,
Gilston, Harlow
Essex  CM20 2RL
United Kingdom

Product Type

SDX-15 Plant Alarm System
Includes
SDX-15 Plant Alarm
SDX-15 Remote & Internal Transmitter
SDX-15 Plant To Alarm Interface
SDX-RTX1 Transmitter
SDX-15 Interfaces

Year of manufacture 

2021

Standards used

To which this declaration relates is in 
conformity with the following standards:

EN60601-1-2 4th Edition 2015

 Emissions Standard for Medical Equipment

EN55011, Class A 2016 + A1:2017

Emissions Standard for ISM Equipment

EN60601-1-2 4th Edition 2015

Immunity Standard for Medical Equipment

EN61000-4-2 2009

ESD Requirements

EN61000-4-3 2006 + A1 + A2

Radiated Susceptibility

EN61000-4-4 2016

Electrical Fast Transient Burst Requirement

EN61000-4-5 2017

Surges Requirements

EN61000-4-6 2014

Conducted Susceptibility

EN61000-4-8 2012

Magnetic Field Immunity

EN61000-4-11 2017

Voltage Dips and Interruptions

Authorised representative

Technical Director

Signature

10

Shire Controls Ltd

Studio 3, Channocks Farm
Gilston
Harlow
Essex
CM20 2RL

Tel. (01279) 434399

www.shirecontrols.com

Summary of Contents for SDX-15

Page 1: ...issue 11 02 06 2021 The SDX 15 Alarm System for Piped Medical Gases...

Page 2: ...IN TELEPHONE 5 GAS CENTRAL LODGE ALARM IN PORTERS 5 GAS REPEATER COMPUTER INTERFACE SDXPIC 4 CORES 5 CORES 5 CORES 2 CORES 2 CORES 2 CORES 2 CORES 2 CORES 2 CORES 2 CORES TYPICAL PLANT ALARM SYSTEM TO...

Page 3: ...on is to be in an alarm condition for a prolonged period e g for pipeline maintenance the re trigger can be prevented by silencing the audible with the Lockout button within the panel large at white p...

Page 4: ...e condition to normal if the condition is not to be used or with a 1k8 resistor if the condition is to be transmitted from another transmitter The resistors are used to prevent a system fault due to s...

Page 5: ...number location and size number of services to be displayed of alarm panel as required by C11 HTM02 01 Select the location and size of transmitters Use internal transmitters if an alarm panel is in th...

Page 6: ...ice fault remains requiring re muting When a condition is to be at alarm condition for a long time the audible can be continuously muted as follows Open the panel and while the alarm condition is pres...

Page 7: ...m fault only appears on one section of the system look for a broken wire or loose terminal between the section with the system fault and the rest of the system Contact Line fault This indicates that t...

Page 8: ...MERGENCY PLANT PLANT FAULT FAULT PLANT PLANT VACUUM AIR MEDICAL CYLINDERS CYLINDERS CYLINDERS CYLINDERS FAULT PRESSURE NORMAL FAULT PRESSURE FAULT RESERVE NORMAL FAULT PRESSURE FAULT RESERVE IMMEDIATE...

Page 9: ...IQUID IMMEDIATELY RESERVE FAULT PRESSURE FAULT NORMAL CHANGE CHANGE IMMEDIATELY RESERVE FAULT PRESSURE FAULT NORMAL CHANGE IMMEDIATELY RESERVE FAULT PRESSURE FAULT NORMAL RESERVE FAULT PRESSURE FAULT...