15
20H/50H
002AH
Transmission output high limit setting
Setting value
20H/50H
002BH
Transmission output low limit setting
Setting value
20H/50H
002CH
Scaling high limit setting
Setting value
20H/50H
002DH
Scaling low limit setting
Setting value
20H/50H
002EH
Decimal point place selection
0000H: No decimal point
0001H: 1 digit after decimal point
0002H: 2 digits after decimal point
0003H: 3 digits after decimal point
20H/50H
002FH
Sensor correction setting
Setting value
20H/50H
0030H
PV filter time constant setting
Setting value
20H/50H
0031H
Setting value lock selection
0000H: Unlock
0001H: Lock
20H/50H
0032H
Step temperature setting value (SV)
(when program control start) setting
Setting value
20H/50H
0033H
Program control start system
selection
0000H: PV start
0001H: PVR start
0002H: SV start
20H/50H
0034H
Status after power failure restored
selection
0000H: Stop
0001H: Continuation
0002H: Halt
20H/50H
0035H
Step time unit selection
0000H: Hour:Minute
0001H: Minute:Second
20H/50H
0036H
Step time indicating method selection
0000H: Step remaining time
0001H: Step time setting value
20H/50H
0037H Step temperature indicating method
selection
0000H: Current step temperature
0001H: Step temperature setting
value
20H/50H
0038H Pattern end output time setting
Setting value
20H/50H
0039H Step temperature setting value (SV)
when program end holding function
selection
0000H: Hold function is not applied
0001H: Hold function is applied
20H/50H
003AH Time signal 1 output/Status output
(RUN) selection
0000H: Time signal 1 output
0001H: Status output (RUN)
20H/50H
003BH Time signal 2 output/Status output
(HOLD) selection
0000H: Time signal 2 output
0001H: Status output (HOLD)
20H/50H
003CH Time signal 3 output/ Status output
(WAIT) selection
0000H: Time signal 3 output
0001H: Status output (WAIT)
20H/50H
003DH Time signal 4 output/ Status output
(FAST) selection
0000H: Time signal 4 output
0001H: Status output (FAST)
20H/50H
003EH Time signal 5 output/ Status output
(STOP) selection
0000H: Time signal 5 output
0001H: Status output (STOP)
20H/50H
003FH
Running pattern number setting
[Effective when 0 is selected by
external Pattern number selection,
and when the mode is in Program
standby. (External selection has
priority.)]
0000H: Running pattern number 0
0001H: Running pattern number 1
0002H: Running pattern number 2
0003H: Running pattern number 3
0004H: Running pattern number 4
0005H: Running pattern number 5
0006H: Running pattern number 6
0007H: Running pattern number 7
0008H: Running pattern number 8
0009H: Running pattern number 9
20H/50H
0040H
Pattern number selection to be set
0000H: Pattern number 0
0001H: Pattern number 1
0002H: Pattern number 2
0003H: Pattern number 3
0004H: Pattern number 4
0005H: Pattern number 5
0006H: Pattern number 6
0007H: Pattern number 7
0008H: Pattern number 8
0009H: Pattern number 9