42(65)
Phase error
Phase disconnect or phase reverse
Activated
Stop
Over temp. ego
Contact input for ego temp. check
Activated
Stop
Over pump
Contact input for pumper overload
check
Activated
Stop
Low press
Contact input for low pressure
check
Activated
Stop
High press
Contact input for high pressure
check
Activated
Stop
L. level water
Contact input for low water level
check
Activated
Stop
Appear
“
-----
“
on
temperature display
Sensor abnormality
Activated
Stop
Dve1 alarm
Deviation between control temp.
and entered temp.
Activated
Maintain its
status
Dev2 alarm
Deviation between control temp.
and retrieved temp.
Activated
Maintain its
status
Turb. Alarm
Control temp. is suddenly dropped
Activated
Maintain its
status
Heater alarm
Control temp. does not rise
Activated
Maintain its
status
Notes: When alarm sounds, controller will automaticlly start the protective function and stop the machine.
Press "ON" to restart the machine.
Summary of Contents for STM-1220-PW
Page 1: ...STM PW Series Hi Temp Water Heater Date Dec 2014 Version Ver B English ...
Page 2: ......
Page 25: ...25 65 2 3 2 Control Circuit STM PW 400V Picture 2 6 Control Circuit STM PW 400V ...
Page 29: ...29 65 2 3 5 Main Circuit STM PW 230V Picture 2 8 Main Circuit STM PW 230V ...
Page 30: ...30 65 2 3 6 Control Circuit STM PW 230V Picture 2 9 Control Circuit STM PW 230V ...
Page 62: ...62 65 ...