96(178)
No
Alarm
Description
Solution
A 020 to
A 027
Servo axis ** position
has exceeded
**is (X/Y/Z/A/B/C/Y2/Z2)
Total 8 axes
Servo operation cannot
follow CNC command
speed
Function/Servo Setup/ Servo operation
parameter
setup/**/
Control
parameter
configuration
–
> Maximum position deviation,
set the first value greater than second value
1mm, second value shows the actual
deviation
Function/Servo Setup/ Servo operation
parameter
setup/**/
control
parameter
configuration -> Set the KV value a bit higher,
recommend to add 50 each time
Adjust operation acceleration, Function/Servo
Setup/ Servo Operation speed configuration
A 028 to
A 035
Servo Axis ** alarm
**is (X/Y/Z/A/B/C/Y2/Z2)
total 8 axesServo error
Module CST022 has not been detected
Module 24V/+5V power supply error
Servo amplifier alarm an error
A 036 to
A 043
Servo axis**minimum
position limit
**is(X/Y/Z/A/B/C/Y2/Z2)t
otal 8 axes
Minimum limit sensor got
signal input
Robot exceed limit position, check robot
Transducer error, check the transducer
A 044 to
A 051
Servo
axis**
maximum
position
limit
**is
(
X/Y/Z/A/B/C/Y2/Z2
)
total 8 axes
Maximum limit sensor
got signal input
Robot exceed limit position, check robot
Transducer error, check the transducer
A 052
Pressed Emergency
stop
Emergency stop button
in the hand controller has
been pressed
Crosswise rotate the emergency button
Function/System setup page,
Stop then
reboot
Function
Open
,
this alarm will only
disappear by reboot. If choose
Close
, the
alarm will disappear automatically
A 053
Pressure error
Air pressure error
Check air source pressure
A 054
Pressed
IMM
emergency
stop
button
Detected
IMM
emergency stop button
has been pressed
Check IMM emergency stop button
Check the wiring
A 055
Safety facilities error
IMM safety door open
Check IMM safety door status
Check the wiring
A 056
Quantity finished
Set quantity has finished
Function/Quantity setup page -> Setup
quantity
A 057
Reject
products
reached the set limit
Reject products reached
the set limit to alarm
Function/Quantity setup page -> Reject alarm
setup
A 058
Exceed cycle time
Cycle time exceed the
set protection time
Function/Quantity Setup -> Motion monitor
time
A 060
Safety zone detection
error
Robot current position
beyond safety zone
Check robot current actual position
Function/Safety point setup page, set the
corresponding safety zone
A 061
Gripper error
Gripper action exceeds
the set monitoring time
Function/Signal setup -> Gripper*Detection
*.**s
A 062
Open mold signal
error
Open mold signal and
close mold signal conflict
Check IMM output signal
A 063
Vacuum error
Vacuum action exceeds
the set monitoring time
Function/ Signal setup -> Vacuum*detection
*.**s
A 064
Axis Z not in home
position
Axis Z deviated from the
home position
Axis Z beyond the origin vertex 1mm
3
cube,
check the actual position of the robot and the
mold open signal
Summary of Contents for ST3 Series
Page 1: ...ST3 5 Fully Servo Driven Robot User Manual Date Jun 2016 Version V1 5 English ...
Page 2: ...2 178 ...
Page 12: ...12 178 ...
Page 121: ...121 178 7 9 ST3 MT Traverse unit Fig 7 11 ST3 MT traverse unit exploded view ...
Page 123: ...123 178 7 10 ST3 MT Crosswise Unit Fig 7 12 ST3 MT crosswise Unit exploded view ...
Page 125: ...125 178 7 11ST3 MT Main arm unit Fig 7 13 ST3 MT Main arm unit telescopic arm exploded view ...
Page 130: ...130 178 7 13 ST3 LT Crosswise Unit Fig 7 15 ST3 LT crosswise unit exploded view ...
Page 132: ...132 178 7 14 ST3 LT Main arm unit Fig 7 16 ST3 LT main arm unit exploded view ...
Page 150: ...150 178 9 15 ST3 SIGMATEK module board Fig 9 15 ST3 SIGMATEK Module board 1 ...
Page 151: ...151 178 Fig 9 16 ST3 SIGMATEK Module board 2 ...
Page 174: ...174 178 10 19 ST5 SIGMATEK module board Fig 10 21 ST5 SIGMATEK module board 1 ...
Page 175: ...175 178 Fig 10 22 ST5 SIGMATEK module board 2 ...