51(64)
1. F-20 functions as an password lock
,
hold on "SET" till the "PV" displays F-20.
2. Press
key and only after input 0021 in the SV
,
can you press
"ENTER" to come into F-03 and other settings
,
so F-20 functions as an
coded lock for entering into next parameters setup, which prevents the
modification from unprofessionals.
Picture 4-8
:
Weekly Time Start Setup 4
3. F-03 stands for the selection of temperature unit. Press
to shift
between
/
℃ ℉
then press
“
ENTER
”
to confirm.
4. F-04 is data lockup function, press
key to shift between OFF / LOCK
,
LOCK is for locking up information
,
not able to input or change any data:
OFF is for lockup cancellation.
Picture 4-9
:
Weekly Time Start Setup 5
5. F-05 stands for the function of temperature protection. Alarm will be launched
if actual temperature were equal to or higher than the addition of setting
temperature value and setting value. This temperature range is between 0
and 50, and default value is 15.
Summary of Contents for SMD-1000H
Page 1: ...SMD H Series Mould Sweat Dehumidifier Date Sep 2014 Version Ver B English...
Page 2: ......
Page 11: ...11 64 1 3 2 Outline Drawing SMD 500H 1000H SMD 1500H 2000H Picture 1 1 Outline Drawing...
Page 15: ...15 64 1 6 Maintenance Schedule Picture 1 3 Maintenance Schedule...
Page 25: ...25 64 2 4 2 Main Circuit SMD 500H 1500H Picture 2 6 Main Circuit 1 SMD 500H 1500H...
Page 26: ...26 64 Picture 2 7 Main Circuit 2 SMD 500H 1500H...
Page 27: ...27 64 2 4 3 Control Circuit SMD 500H 1500H Picture 2 8 Control Circuit SMD 500H 1500H...
Page 33: ...33 64 2 4 7 Main Circuit SMD 2000H Picture 2 11 Main Circuit 1 SMD 2000H...
Page 34: ...34 64 Picture 2 12 Main Circuit 2 SMD 2000H...
Page 35: ...35 64 2 4 8 Control Circuit SMD 2000H Picture 2 13 Control Circuit SMD 2000H...