Shindaiwa Limited
POWERCENTER 15
Four Ashes, Wolverhampton, UK
PC15-OM-Vs: 1
T: +44 (0)1902 791855
Lifting Lug
Spill
Containment
Bolt (M8)
・
Right: 4 bolts
・
Left: 3 bolts
(8) Cleaning/Inspecting the Spill Containment
Clean / Inspect
Every 400 hours or 1 year
Caution: Injuries
Always be sure to use the lifting lug when lifting the equipment, and lift slowly and
directly straight above.
Wear a helmet, safety shoes, gloves and similar protective gear when performing
lifting work. Do not stand or get under the equipment while it is suspended.
For cleaning/inspecting the spill containment, set this equipment with it situated on
a stable level surface so that it is prevented from moving.
1)
Drain the spill from the
containment.
2)
Remove the seven installation
bolts (M8) of the spill
containment.
3)
Lift up the equipment body to
separate the spill containment
and set the equipment on a
level surface.
4)
Clean the inside of the spill
containment using a high-
pressure washer or similar
equipment.
5)
Drain the cleaning liquid from
the spill containment.
6)
Remove any rust that has
formed in the spill
containment and paint it
again.
7)
Pour water into the spill
containment and check that
there is no leakage.
(After checking, drain the
water you have used.)
8)
Install the spill containment to
the equipment in the reverse
order of removal.
<Note>
Do not operate the equipment with the spill containment separated.
If liquid drained from the spill containment during cleaning contains oily components,
dispose of it in a manner according to the applicable laws and regulations. If the spill
containment has a leak, request repair at the retail outlet where the equipment was
purchased.
給水口
-40-