startIng
cold
engIne
• Provide all operators of this equipment with the Operator's Manual
and instructions for safe operation.
• Before starting the unit, equip yourself and any other person work
-
ing within the 15 m (50 ft.) Safety Zone with the required Protective
Equipment and clothing.
1.
Stop Switch
Move stop switch button (A) away from the STOP position.
2.
Throttle Position
Move throttle position lever (B) midway between idle and full
throttle positions.
3.
Choke
Move choke (C) to "Cold Start" (
) Position.
4.
Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope for start-
ing. Do not allow the rope to snap back in. Always hold the unit
firmly.
5.
Recoil Starter
Place the unit on a flat, clear area. Firmly grasp throttle grip with
left hand and rapidly pull recoil starter handle/rope (E) until en-
gine fires (5 pulls maximum).
11
Eng
lish
s
tartInG cold enGIne
• Provide all operators of this equipment with the Operator's Manual
and instructions for safe operation.
• Before starting the unit, equip yourself and any other person work-
ing within the 15 m (50 ft.) Safety Zone with the required Protective
Equipment and clothing.
Stop Switch
Move stop switch button (A) away from the STOP position.
Throttle Position
Move throttle position lever (B) midway between idle and full throttle
positions.
1.
2.
A
B
Choke
Move choke (C) to "Cold Start" (
) Position.
Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the clear
fuel tank return line. Pump bulb an additional 4 or 5 times.
IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope for starting.
Do not allow the rope to snap back in. Always hold the unit firmly.
Recoil Starter
Place the unit on a flat, clear area. Firmly grasp throttle grip with left
hand and rapidly pull recoil starter handle/rope (E) until engine fires (5
pulls maximum).
Choke
After engine fires (or 5 pulls), move choke lever to “Run” (
) posi-
tion and pull starter handle/rope until engine starts and runs. Allow unit
to warm up at idle for several minutes.
NOTE
If engine does not start with choke in “Run” position after 5 pulls,
repeat instructions 2- 5.
After engine warm up, gradually depress throttle trigger to increase
engine RPM to operating speed.
3.
4.
5.
6.
7.
C
D
E
IMPORTANT
Spilled fuel is a leading cause of hydrocarbon emissions. Some
states may require the use of automatic fuel shut-off containers
to reduce fuel spillage.
After use
• DO NOT store a unit with fuel in its tank. Leaks can occur. Return
unused fuel to an approved fuel storage container.
Storage -
Fuel storage laws vary by locality. Contact your local gov-
ernment for the laws affecting your area. As a precaution, store fuel in
an approved, airtight container. Store in a well-ventilated, unoccupied
building, away from sparks and flames.
IMPORTANT
Stored two-stroke fuel may separate. ALWAYS shake fuel con-
tainer thoroughly before each use.