44
CAUTION : FIRE
Do not carry flammable items (such as fuel, gas and paint) or items that are
highly combustible near the generator as the muffler, exhaust gas and other
parts become extremely hot.
Position this generator 3 ft. (1 m) or more from walls or other hindrances, and
on a level surface.
CAUTION : INJURY
Do not operate the generator if it has been modified or any parts have been
removed.
Position the generator on a level stable surface so that it cannot slide or
move in any manner.
Before starting operation, always be sure to turn off all switches of equipment
being used and all breakers to OFF.
Clean
Every 250 hours
Accumulation of carbon (soot, unburned fuel) in the exhaust pipe line and muffler could
cause only a system derates or an engine fault occurs. To destroy the soot and unburned
fuel, run the unit at rated power for some period of time until the exhaust gas become
mostly colorless every 250 hours operation time. The carbon will be easier to be generated
when the unit operates at less then 30% of rated power. In this case, perform the above
procedures at shorter interval time.
< Note >
When the unit operates at rated power, accumulation of carbon in the exhaust pipe line and
muffler might be lead to back fire incident. Do not carry flammable items that are highly
combustible near the generator.
11. Long-Term Storage
WARNING : INJURY
Always be sure to stop the engine and remove the starter key when
performing inspection or maintenance.
CAUTION : FIRE
Always be sure to wipe up any spilled fuel or oil.
Allow the generator to cool before covering with the protective cover.
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after
stopping the engine as they are still extremely hot.