11 long-term Storage
:
Electrical Shock
●
Injuries
Before performing any equipment check or maintenance, stop the engine, and remove the
engine key. A person performing the maintenance should always keep the key.
:Fire
●
Burns
Temperature around muffler and exhaust can get extremely high. Keep any inflammable
items (such as fuel, gas, paint, etc.) away from the equipment.
When checking engine, always stop the engine, and keep away from fire. Wait until the
engine cools down, before performing any checks.
Always wipe any drip of Diesel fuel or oil. Do not use this equipment when a leak is found.
Repair the equipment before use.
11.1 Storage Procedures
If the generator will not be used for more than two months, perform the following maintenance
and storage procedures.
①
Remove battery
②
Change engine oil
③
Drain fuel from fuel tank and fuel filter
④
Clean all parts, cover the generator, and keep it in the storage, away from dust and
humidity.
<Caution>
Recharge the removed battery once a month.
Refer to the user’s manual for the care of the engine
.