Shimax MAC3 Series Instruction Manual Download Page 3

Press      (DOWN) key one time, and the shown value decreases by one 
numerical value.
One time press of       key decreases by one numerical value. By pressing the 
key continuously, the value as well consecutively decreases. A decimal point of 
the smallest digit blinks at this time. This shows that a setting change is in 
progress. In PROG, used as a shift key between each step setting screens (Steps 
1-25), lead screen. Also used as a shift key between lead screen in each mode 
screens.

3

4. Description of front panel

4-1. Names of front panel.

3-5

Terminal arrangement diagram

4-2. Explanation of front panel section

 : Display of measured value (PV)  (red)

       Measured value (PV) and type of setting is displayed on each setting screen.

 : Display of target value (SV)  (green)

        

Target value and set value are displayed on each setting screen.

RUN monitor LED                                RUN       (green)
If RUN is performed with RUN key, operation mode1 screen, external control 
input (DI), and communication, it lights up, and put out by standby (reset). It 
blinks, if a manual output is chosen in output monitoring screen or external 
control input (DI).
Program functional monitor LED          PRG       (green)
Lights up at the time of program control's standby or flat part control. Puts out 
at the time of FIX control selection. 
Auto tuning operation monitor LED        AT        (green)
If AT is chosen in ON or external control input (DI), blinks during AT 
execution. Lights up when AT is on standby, and puts out with AT automatic 
termination or release. 
control out put 1 monitor LED 

    

OUT1

   

(green)

At the time of a contact or a voltage pulse output, the it lights up with ON and 
lights off with OFF. Lights off with 0% power output, and lights up with 100% 
power.
And blinks in intermediate ratio.
Event output monitors LED                   EV1 and EV2       (yellow)
Lights up when the allotted event output turns to ON.
Control out put 2/event output 3 monitors LED  OUT2/EV3    (yellow)
When control output 2 is chosen, it operates like control output 1 monitor LED 
does.
When event output 3 is chosen, it operates like event output monitor LED does.

Press this key to move onto the next screen among the screens.
Press      (MENU) key for three seconds on the basic screen, then it jumps to 
the lead screen of Mode 1. Press      key for three seconds on the lead screen of 
each Mode screens, then it jumps to the basic screen.Press      key for three 
seconds on the lead screen of FIX or PROG, then it jumps to the basic 
screen.When a program control option is added, press      (MENU)  key for 
three seconds on the screen of operation mode 2, then it jumps to the screen of 
operation Mode 1. 

 : Monitor LED

(MENU) key

 Key-switch section

 3-5. Terminal arrangement plan of MAC3A and MAC3B 

If input type is thermocouple or voltage, errors may occur when terminal  
8 and terminal 9 terminal are short-circuited 

NOTE

 : 

If input type is thermocouple or voltage, errors may occur when terminal  
5 and terminal  6  terminal are short-circuited 

NOTE

 : 

Terminal arrangement plan of MAC3D

MAC3A

  

96×96size

  

front

MAC3C

  

72×72size

  

front

MAC3D

  

48×48size

  

front

MAC3B

  

48×96size

  

front

(1) 

(1) 

(2) 

(3) 

(4) 

(5) 

(6) 

(DOWN) key

(2) 

Press      (UP) key one time, and the shown value increases by one numerical 
value.
By pressing continuously, the value By pressing the key continuously, the value 
consecutively increases. A decimal point of the smallest digit blinks at this time. 
This shows that a setting change is in progress. In PROG, used as a shift key 
between each step setting screens (Steps 1-25), lead screen. Also used as a shift 
key between lead screen in each mode screens. (1

40step will be added from 

ver1.3)

(UP) key

(3) 

Push for 3 seconds at STBY (control stop), then FIX or PROG control starts.
Push for 3 seconds while FIX or PROG is in operation, then control is stopped.

(RUN OPERATION/STOP) key

(5) 

The setting data changed on each screen is determined (the decimal point of the 
minimum digit is also lighted off).
When a program control option is added, press      (ENT) key for three seconds 
on the screen of operation mode 1, then it jumps to the screen of operation 
Mode 2.

  

Press      key for 3 seconds on the output monitoring screen,then the shift 
between manual output and automatic output is carried out. 
Press the key for 3 seconds on the basic screen, then it shifts to FIX or PROG 
head screen.
Push at FIX-PROG and each mode screens' lead screen, then shifts to setting 
screen.

(ENTRY/REGISTER) key

(4) 

If input type is thermocouple or voltage, errors may occur when terminal 
11 and terminal 12 terminal are short-circuited 

NOTE

 : 

Terminal arrangement plan of MAC3C 

Summary of Contents for MAC3 Series

Page 1: ...t 7 DI N none D external control input DI 1 2 3 three points 8 CT Input N none H CT Input two points 9 Analog Output N none T current 4 20mA V voltage 0 5V 10 Communication N none R RS485 11 Program F...

Page 2: ...dimension and panel cutout MAC3 external dimensions unit mm MAC3 panel cutout unit mm Do not turn on electricity while wiring to avoid an electric shock Do not touch a terminal or live part while turn...

Page 3: ...c screen then it jumps to the lead screen of Mode 1 Press key for three seconds on the lead screen of each Mode screens then it jumps to the basic screen Press key for three seconds on the lead screen...

Page 4: ...ol stop Output OFF 0 operation conduct of control operation Choose RUN by key Decide by key then Monitor LED s RUN lights up to start control operation Initial value stanby Initial value at the time o...

Page 5: ...lized when measuring range unit and scaling are changed Lower limit value of target value is set The operation mode of each deviation alarm is Effective at the time of automatic output Each deviation...

Page 6: ...peration or PI operation in D OFF setting The offset correction at the time of I OFF P operation PD operation is performed This screen is not displayed at the time of ON OFF operation The differential...

Page 7: ...1 standby operation setting screen Event 1 latching setting screen Event 1 output characteristics setting screen Event 2 mode setting screen Initial value 0 0 Setting range 0 0 99 9 Contents is the s...

Page 8: ...tion is possible no decimal pont 0 1 0 01 0 001 Unit Code Measureing Range Input Type Code Unit Code The same as event 1 Event 2 output characteristics setting screen Initial value Setting range The s...

Reviews: