4.2.B
Welding parameters control panel
Welding parameters adjustment
To change value of desired parameter it needs to be selected with the press of selection knob and then
with turning the knob set the specific value. Currently selected parameter is indicated by corresponding
LED light. LCD screen shows actual value of the parameter, turning the adjustment knob to the right
increases the value, turning it to the left decreases it. Confirming your selection by pressing the knob. It
automatically jumps to the next parameter.
Settings memory
Device has a memory module to store up to 10 sets of settings of welding parameters. It also keeps the
last used settings in the memory after device has been turned off.
To store a specific set of settings press the SAVE/LOAD button
for 3 seconds. “Save” LED indicator will
turn on. It means that you can save your settings under one of the sets number from 1 to 10. To change
the set number use adjustment knob. After desired set number is selected press the knob to save it.
Please remember that if you save your settings under previously used number the previous settings will
be overwritten.
To restore a specific set of settings from the device memory quickly press and release the SAVE/LOAD
button
. After “Load” indicator light is on use the adjustment knob to choose desired set number and
press the knob to load it.