8
A - Pulse on / off button
Only active when TIG welding. Mode selection is signaled by the lighting of the symbol
- pulse welding,
- pulseless welding.
B - Welding method selection button
The button is used to select the welding method. The choice of method is signaled by the lighting of the symbol:
MMA
- covered electrode (MMA) welding, LI FT - gas shielded tungsten electrode welding
MMA
- covered electrode (MMA) welding, LI FT - gas shielded tungsten electrode welding
protective devices with arc ignition by rubbing (TIG Lift), H.
F -
welding with tungsten electrode in shielding gases with pilot arc (TIG HF).
protective devices with arc ignition by rubbing (TIG Lift), H.
F -
welding with tungsten electrode in shielding gases with pilot arc (TIG HF).
protective devices with arc ignition by rubbing (TIG Lift), H.
F -
welding with tungsten electrode in shielding gases with pilot arc (TIG HF).
protective devices with arc ignition by rubbing (TIG Lift), H.
F -
welding with tungsten electrode in shielding gases with pilot arc (TIG HF).
protective devices with arc ignition by rubbing (TIG Lift), H.
F -
welding with tungsten electrode in shielding gases with pilot arc (TIG HF).
C - Control knob
The adjustment knob is used to change the welding parameters.
Briefly pressing the knob causes the transition between the parameters being set. The currently adjustable parameter is marked by the lighting of the
corresponding diode, and the current parameter value appears on the parameter display (I). Turning the knob to the left decreases it, and turning it to
the right increases the parameter value. Pressing the knob again will save the parameter value and go to the next parameter.
D - Settings memory
The device has the memory of the last setting, i.e. after turning it off and on again, the last set parameters are restored. It is also possible to
save a total of 20 sets of settings for TIG HF and MMA welding methods.
To call up a previously stored set of settings, press the button
until displayed
the corresponding set number on the memory display (H).
If after calling the set of settings we change any of the parameters, the device will exit the memory mode - a dash will appear on the memory display (H)
and the diode will turn off
USER
The changed parameters will be automatically cached after 30 seconds. After the device is turned off and restarted, they
and the diode will turn off
USER
The changed parameters will be automatically cached after 30 seconds. After the device is turned off and restarted, they
and the diode will turn off
USER
The changed parameters will be automatically cached after 30 seconds. After the device is turned off and restarted, they
will be restored and a dash will appear on the memory display.
To save the current settings, press the button
and hold for 2 seconds. Will light up
diode
USER,
and the number on the memory display (H) will flash. Turn the knob to change
diode
USER,
and the number on the memory display (H) will flash. Turn the knob to change
diode
USER,
and the number on the memory display (H) will flash. Turn the knob to change