Shenzhen TZONE Digital Technology CO.,LTD.
TZ-AVL19 user manual
X=C means the output port 3
X=D means the output port 4
Y=0, Out port is low (the oil
of circuit is restore) (default)
Y=1, Out port is high ( the oil
of circuit will cut off )
For Example:
*000000,025,A,1#
028
iButton function
*$$$$$$,028,X,Y#
X:1: enable;
0 :disable(default);
Y:I/O output port option
0:disable(default);
1: output port 1;
2: output port 2;
3: output port 3;
if read iButton ID when enable
Y, output port will enable 3S,
can control the iButton lamp or
buzzer, etc.
040
Heart Beat Switch
*$$$$$$,040,X#
X=0 Disable the heart beat
function (default)
X=1 Enable the heart beat
function
041
Heart Beat Intervals
*$$$$$$,041,X#
X is the heart beat interval,
unit is minute [1<X<9999]
(default:720)
X=0, Disable this function.
042
Heart Beat Init
*$$$$$$,042,0#
When receive this command,
the heart beat will re-count
time
046
Set sleep module
*$$$$$$,046,X,Y,Z,ABCDEF
G#
X=0 Disable sleep
unction (default)
X=1 Enable sleep Function
Y: the time of freedom,
means if there is no duty, [20
– 65535] unit sec, 900 is
default.
Z: the time of wake up from
sleep module when the AVL19
begin motive. [20,600], unit is
sec, default 30s.
A=1: when no RFID tag means
no duty.
B=1: when engine has
been close means no duty.
C,D,E,F,G: obligate
Summary of Contents for TZ-AVL19
Page 9: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual 1 3 5 Detect Car ON OFF ...
Page 43: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 44: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 45: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 46: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 47: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...