Shenzhen TZONE Digital Technology CO.,LTD.
TZ-AVL19 user manual
002
Set the time
intervals of
position notice
SMS
The Position SMS
will be sent to the
preset SOS phone
number.
*$$$$$$,002,X,Y#
X
(Max
5
Digital)
=0, Stop send position SMS
(default)
=[1,60000] Time interval
(Unit: mins)
Y
(Max
3
Digital)
=[1,999] times send SMS
Y=0,
Disable
this
function (default)
Y=999, continue sending
SMS
003
Set a preset phone
& SMS number
for SOS button
*$$$$$$,003,P,F,CallNumber
, SMS Number#
P= 0, Disable photo function
(default)
P= 1, Only Camera 1 get
picture
P= 2, Only Camera 2 get
picture
P= 3, Both Camera 1 and 2 get
picture
F = 0, Disable SOS alarm
function (default)
F =1, Only send an alarm
SMS to the preset SMS
Number Notice: Call Number
and SMS Number ( must <25
digits)
004
Set
low
power alarm
When
the
AVL
voltage
is
lower
than
the
preset
value, AVL will send
one lower power
alarm GPRS data to
the Preset Server.
*$$$$$$,004,XXX,YYY#
XXX is the low power alarm
voltage, eg.: 3.8v,XXX=380
(default:360)
YYY is the auto shut
down voltage, eg.: 3.5v,
YYY=350 (default:340)
For example:
*$$$$$$,004,380,350#
005
Set
over
speed
alarm
When
the speed
of the AVL is
higher than the
preset, value,
*$$$$$$,005,S,X,Y,Z#
S=1
Enable
speed
alarm,
S=0
Disable
speed alarm. (default)
X=[10<XXX<250] (The
speed preset value)
unit is km/h
Summary of Contents for TZ-AVL19
Page 9: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual 1 3 5 Detect Car ON OFF ...
Page 43: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 44: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 45: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 46: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 47: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...