5-14
VL-H870U
VL-H875U
VL-H890U
VL-H860S/H/VL-H870S
VL-H890S/VL-H94E
VL-H96E/VL-H960E
VL-H860S/H/VL-H870S
VL-H890S/VL-H94E
VL-H96E/VL-H960E
5-4-2-1. Checking the power supply voltage
•
Measuring terminal: CAM 4.9V
CAM 2.8V
CAM 3.1V
CAM 15V
CAM -7V
LENS 5V
•
Measuring instrument: Digital voltmeter
5-4-2-3. Adjustment of Camera signal
•
Before starting these adjustment, auto focus adjustment must be finished.
•
Set up the camera signal adjustment mode (Write 00 to the address 1FE)
1. Sync level adjustment
Measuring instrument
Oscilloscope
Subject
Anything
Tape
—
Test point
VIDEO OUT (Terminated in 75
Ω
)
Adjustment address
1F8
Adjustment level
300mVp-p
1) Connect the oscilloscope to the VIDEO-OUT. Adjust the sync
level to 300mVp-p.
1H
Video
SYNC
300mVp-p
5-4-2-2. Auto focus adjustment
Measuring instrument
None
Subject
—
Tape
—
Test point
None
Adjustment address
1FF
Adjustment level
09, 0A, 0B
•
Basic iris adjustment
1) Set up the auto focus adjustment mode. (Write 01 to the address 1FE)
2) Write the adjustment data 09, 0A and 0B one after the other to the address 1FF, the adjustment are as above.
DATA
Adjustment
09
Hall offset
0A
Iris offset
0B
Iris close
•
Lens adjustment
Measuring instrument
None
Subject
More than 50 m away
Tape
—
Test point
None
Adjustment address
1FF
Adjustment level
11, 12, 06, 08, 0D
DATA
Adjustment
11
Voltage adjustment
12
Optical wide-end adjustment
06
Wide-end focus
∞
position adjustment
08
Tele-end focus
∞
position adjustment
0D
Zoom tracking adjustment
1) Set up the auto focus adjustment mode.
(This is unnecessary after the above basic iris adjustment has been made.)
2) Write the adjustment data 11, 12, 06, 08 and 0D one after the other to the address 1FF. The adjustments are as above.
Write FF to the address 1FE to exit the auto focus adjustment mode.
700mVp-p
Measuring instrument
Oscilloscope
Subject
Gray scale
Tape
—
Test point
VIDEO-OUT
Adjustment address
1FC
Adjustment level
700mVp-p
1) Shoot the gray scale in the standard way. Observe the VIDEO-OUT signal on the oscilloscope screen and rewrite the data of
address 1FC to get an amplitude of 700mVp-p as shown above.
2. Iris AE adjustment
3. Black balance , AF noise level adjustment
Measuring instrument
None
Subject
Anything
Tape
—
Test point
None
Adjustment address
1FF
Adjustment level
01
1) Preparation : Write FF to address 19C, 19D, 19E, 19F, 1AO,
1AI.
2) Write the data 01 to the address 1FF.
The following adjustments are automatically
carried on ;
1
Black balance adjustment
2
AF noise level adjustment
at AGC Gain Min , AGC Gain Max and Gain up.
3) Data processing after adjusting the noise level calculation
formula (Round off fractions).
Summary of Contents for VL-H860H
Page 79: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 32 10 11 12 13 14 15 16 17 18 19 ...
Page 89: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 42 10 11 12 13 14 15 16 17 18 19 ...
Page 99: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 52 10 11 12 13 14 15 16 17 18 19 ...
Page 101: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 54 10 11 12 13 14 15 16 17 18 19 ...
Page 111: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 64 10 11 12 13 14 15 16 17 18 19 ...
Page 113: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 66 10 11 12 13 14 15 16 17 18 19 ...
Page 119: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 72 10 11 12 13 14 15 16 17 18 19 ...
Page 121: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 74 10 11 12 13 14 15 16 17 18 19 ...
Page 123: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 76 10 11 12 13 14 15 16 17 18 19 ...
Page 125: ...VL H860S H VL H870S VL H890S VL H94E VL H96E VL H960E 7 78 10 11 12 13 14 15 16 17 18 19 ...